4.

 

PUMP CUT-OUT – 

The ESC System features a protective interlock system which cuts off

power  to  the  pool  pump  if  there  is  no  water  flowing  through  the  cell  housing.   This  is
especially helpful if the pump ‘runs dry’ and hence may stop the pump motor from burning
out.

CHLOROMATIC

 MODEL ESR and ESC SERIES SPECIAL FEATURES

STAND- BY:

The 

Stand - By

 indicator will be On when the Unit is preparing to produce sanitiser. This will be

either during the systems initial start up or when the Cell has been turned Off during the filtration
cycle.

FLOW:

If there is a problem with water flow or gas is detected in the Cell Housing the 

fIow

 indicator will

be On. When this occurs the pump or pipes should be inspected for damage and the Flow Sensor
connection checked.

SYSTEM CONTROL

:

The System Control varies the amount of time the Cell operates during the filtration cycle.

The 

System Control

 will 

not

 vary the electrical current supplied to the Cell. (As shown on the

Display).

As an example, if one filtration cycle is set at 5 hours, and the 

System Control

 is set to 80%, then

the  total  amount  of  time  the  Cell  will  operate  during  the  5-hour  cycle  will  be  4  hours.  If  the

System  Control

 is set to 60%, the Cell will operate for 3 hours total over the 5-hour filtration

cycle.

When the 

System  Control

 is set to MIN, the Cell will be OFF for the duration of the filtration

cycle.  When  the 

System  Control

 is set to MAX, the Cell will be ON for the duration of the

filtration cycle.

The 

System Control

 is graduated in steps of 10% from MIN (OFF) to MAX (ON).

During the filtration cycle, the Cell will be turned ON and OFF a number of times each hour,
unless the 

System Control

 is set at MIN or MAX. Using the previous example (of 60%), the Cell

will operate for about 36 minutes each hour. This 36-minute operating time will be made up of a
number of smaller operating periods. As an example, the Cell may turn ON 12 times (for a period
of 3 minutes each time) over the hour to make up the 36 minutes. This enables the electronic
circuitry to re - adjust to any changes in the pool water condition. For example, dilution from
winter rains, the addition of salt etc.

If the Cell is OFF and you wish to check its operation, simply turn the 

System Control

 to MAX

and the Cell will turn ON. Once checked, adjust the 

System Control

 back to the desired position

and after a few minutes the Cell will turn OFF again.

To  turn  the  Cell  OFF,  simply  turn  the 

System  Control

 to MIN. This will be convenient for

backwashing.

Содержание Chloromatic ESC 16

Страница 1: ...phone 08 9457 9633 NSW STATE OFFICE 1 745 The Horsley Drive Smithfield NSW 2164 Telephone 02 9725 4933 Fax 02 9604 9755 QLD STATE OFFICE 5 37 Northlink Place Virginia QLD 4014 Telephone 07 3266 4711 Fax 07 3266 4722 SA STATE OFFICE 396 North East Road Windsor Gardens SA 5087 Telephone 08 8261 2692 Fax 08 8369 3270 USA CORPORATE HEADQUARTERS Ecomatic Salt Water Pool systems Telephone 949 673 5787 F...

Страница 2: ...ocedure Page 5 6 Operation of Chloromatic System ESR and ESC Series Chloromatic Model ESR and ESC series Special Features Page 7 Standby Flow and System Control Page 8 Low Salinity Indicator and Winter Mode Page 9 Optional Features Time Clock and Light Transformer Page 9 Maintenance of Power Supply Page 10 11 Maintenance of Electrolytic Cell Page 11 12 Day to Day Operation Stabiliser pH and Total ...

Страница 3: ...3 a Electrolytic Cell ESR Series OR b ESC Series Chloromatic Self Clean Standard Mesh Cell or optional Cell Plate cell not shown 4 Warranty Card 5 Cell Adaptors 2 6 Mounting Screw Wall Plug Kit with Spare Fuse Please note product specifications are subject to change without notice and components pictured above may vary from the product contained in your carton Please consult your Chloromatic deale...

Страница 4: ...itting Power Supply to a brick or concrete wall When mounting to a post drill pilot holes and fit screws provided Once screws are in position simply hang Chlorinator via bracket on back of Unit CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY The Power Supply is fitted with a flexible lead terminated with connector s These must be correctly fitted to the connections on the inside of the Cell H...

Страница 5: ...r run the chlorinator system continuously for at least 24 hours or until a reading of 3 ppm is reached STABILISER It is essential that pool stabiliser be added and maintained at the rate of 30 50 mg l 30 50 ppm at all times Do not exceed 100 ppm Refer Day to Day Operation pages 11 12 for further information OPERATION OF CHLOROMATIC ESR SYSTEM Cell Output is expressed as a percentage The Digital LE...

Страница 6: ...low minimum Add Salt 2 Cell is calcified Clean Cell 3 Water temperature very cold Switch to Winter Mode Continued Operation may cause damage to system Consult dealer for problem rectification PLEASE NOTE When Winter Mode switch is On Unit will operate similar to above except Display will fluctuate around 85 Refer Winter Mode page 8 OPERATION OF CHLOROMATIC ESC SYSTEM The Chloromatic ESC system ope...

Страница 7: ... will be 4 hours If the System Control is set to 60 the Cell will operate for 3 hours total over the 5 hour filtration cycle When the System Control is set to MIN the Cell will be OFF for the duration of the filtration cycle When the System Control is set to MAX the Cell will be ON for the duration of the filtration cycle The System Control is graduated in steps of 10 from MIN OFF to MAX ON During...

Страница 8: ...raws less than 80 of maximum current To keep a failed Cell in operation Winter Mode can be used along with extra salt There will come a time when the Cell will not respond to either extra salt or Winter Mode It will then need to be replaced Please note that the Low Salinity Indicator is not like T D S meters which are temperature compensated Scientific Instruments The accuracy will be within 500pp...

Страница 9: ...ights Please Note Only one light can be connected to each light transformer If more than one light is required please refer to your Chloromatic dealer If your unit is fitted with the multi voltage light transformer please ensure it is wired as follows CONNECTION OF LIGHT TRANSFORMER NOTE WIRES FROM LIGHT ARE NOT COLOUR CODED WHITE CONNECT LIGHT WIRES TO VOLTAGE 22V RED WHITE BROWN 12V 12V RED WHIT...

Страница 10: ...viously more in summer The intervals between cleaning could get longer to the point where cleaning is only necessary a few times each year One exception is the use of bore water or ground water in which case cleaning may always need to be as frequent as once a week Life of Chloromatic electrolytic cells vary substantially from one installation to another due to variations in operating time water q...

Страница 11: ...is no water flow Chloromatic Units are also fitted with a Thermal Cut Out to prevent overheating If the temperature rises too high power is automatically disconnected The Unit will resume operation when it cools down DAY TO DAY OPERATION Four Prime rules must be observed if your unit is to give the best possible service 1 STABILISER The importance of pool stabiliser cannot be over emphasised It is...

Страница 12: ... exceed 7000 ppm however no problems will result if this occurs Chloromatic ESR Series chlorinators can be operated in Sea Water Please note ESC Systems salt level must not exceed 6000ppm Consult your local Chloromatic Dealer for more information Salt is the essential element by which your Unit operates Not enough salt means not enough chlorine this simple rule governs the total operation of your ...

Страница 13: ...r the running times can be reduced slightly or the System Control can be turned anti clockwise Test your chlorine level again the following morning at around the same time If your chlorine level is still high repeat the above process until the correct level is attained SUPER CHLORINATION Periodically especially during extremely hot conditions it may be necessary to boost the amount of chlorine in ...

Страница 14: ...ite and the cost of operating the vehicle This fee will not apply if the Unit is returned to the Distributor in your State for repairs If an authorised technician is required to service your Unit and it is found that such services are not covered by warranty labour charges will apply Refer back page of this manual for list of warranty repair agents Monarch Industries strives to reduce or eliminate...

Страница 15: ...6 Chlorinator 3 amp fuse blown 7 Dirty Cell 8 Filter needs backwashing 9 Gas Sensor not connected 10 Running times incorrect 11 Main house fuse blown 12 Pump motor faulty Low Chlorine Production Check for 1 Dirty Cell clean if required 2 Filter needs backwashing 3 Display not at correct production level Cell failing 4 Winter Mode turned On 5 Pool stabiliser too low 6 pH too high 7 Salt level too l...

Страница 16: ...Please note this page has deliberately been left blank ...

Отзывы: