Once the salt level in the pool is correct the Unit may be switched On. The 

Stand - by

 indicator

will be On and no 

Cell  Output

 will be seen for approx 30 seconds, this allows the pump and

filter to prime and the Cell Housing to fill with water. After this start - up delay the Display
should light up fluctuating around 100, unless in 

Winter Mode

 where it will fluctuate around 85.

At this point both 

Operation LED's

 should be Green; if not there is a problem. (Refer table).

DISPLAY/INDICATOR

LED 1

LED 2

REASON/ACTION

STAND – BY 

ON

Green

Green

1.

 

Start – up delay functioning.

2.

 

System Control

 set below max.

Cell is turned off.  (Refer 

System

Control 

page 7).

FLOW
STAND – BY

 ON

Green

Green

1.

 

Gas detected. Check   pump/pipes
for damage.

2.

 

Gas sensor not connected to cell

FLUCTUATING
AROUND 100

Green

Green

System operating normally

Green

Red

1.

 

Salt level too low.  Add salt at a
rate of 25kg per 25000L.

2.

 

Cell is calcified.  Clean cell.

3.

 

Water temperature low. Switch to

Winter Mode.

Red

Red

1.

 

Salt Level below minimum. Add
Salt.

2.

 

Cell is calcified. Clean Cell.

3.

 

Water temperature very cold.
Switch to 

Winter Mode.

Continued Operation may cause
damage to system – Consult dealer
for problem rectification

PLEASE NOTE: When Winter Mode switch is On Unit will operate similar to above except Display will fluctuate
around 85. (Refer Winter Mode page 8).

OPERATION OF CHLOROMATIC

 ESC SYSTEM

:

The Chloromatic

 ESC system operates similarly to the ESR System described above.  The ESC

system has the following additional features:

1.

 

POLARITY INDICATOR ON OUTPUT Display - 

The

 

±

 Symbol

 appears before the cell

output  display  to  indicate  which  polarity  the  system  is  in,  i.e.  positive  or  negative.   This
symbol will alternate and is factory pre set.

2.

 

SYSTEM CONTROL -

 When adjusting the 

System Control (refer following section) 

the

ESC system’s Cell Output Display flashes the control setting (i.e. percentage of time that the
Cell  operates  during  the  filtration  cycle)  for  a  few  seconds  then  resumes  displaying  Cell
Output.

3.

 

CLEANING  OF  CELL  – 

The  ESC  System  uses  a  patented 

Electronic  Self  Cleaning

system to clean your Cell and therefore you should not have to clean your ESC cell unless
you have extreme water conditions.

Содержание Chloromatic ESC 16

Страница 1: ...phone 08 9457 9633 NSW STATE OFFICE 1 745 The Horsley Drive Smithfield NSW 2164 Telephone 02 9725 4933 Fax 02 9604 9755 QLD STATE OFFICE 5 37 Northlink Place Virginia QLD 4014 Telephone 07 3266 4711 Fax 07 3266 4722 SA STATE OFFICE 396 North East Road Windsor Gardens SA 5087 Telephone 08 8261 2692 Fax 08 8369 3270 USA CORPORATE HEADQUARTERS Ecomatic Salt Water Pool systems Telephone 949 673 5787 F...

Страница 2: ...ocedure Page 5 6 Operation of Chloromatic System ESR and ESC Series Chloromatic Model ESR and ESC series Special Features Page 7 Standby Flow and System Control Page 8 Low Salinity Indicator and Winter Mode Page 9 Optional Features Time Clock and Light Transformer Page 9 Maintenance of Power Supply Page 10 11 Maintenance of Electrolytic Cell Page 11 12 Day to Day Operation Stabiliser pH and Total ...

Страница 3: ...3 a Electrolytic Cell ESR Series OR b ESC Series Chloromatic Self Clean Standard Mesh Cell or optional Cell Plate cell not shown 4 Warranty Card 5 Cell Adaptors 2 6 Mounting Screw Wall Plug Kit with Spare Fuse Please note product specifications are subject to change without notice and components pictured above may vary from the product contained in your carton Please consult your Chloromatic deale...

Страница 4: ...itting Power Supply to a brick or concrete wall When mounting to a post drill pilot holes and fit screws provided Once screws are in position simply hang Chlorinator via bracket on back of Unit CONNECTING THE ELECTROLYTIC CELL TO THE POWER SUPPLY The Power Supply is fitted with a flexible lead terminated with connector s These must be correctly fitted to the connections on the inside of the Cell H...

Страница 5: ...r run the chlorinator system continuously for at least 24 hours or until a reading of 3 ppm is reached STABILISER It is essential that pool stabiliser be added and maintained at the rate of 30 50 mg l 30 50 ppm at all times Do not exceed 100 ppm Refer Day to Day Operation pages 11 12 for further information OPERATION OF CHLOROMATIC ESR SYSTEM Cell Output is expressed as a percentage The Digital LE...

Страница 6: ...low minimum Add Salt 2 Cell is calcified Clean Cell 3 Water temperature very cold Switch to Winter Mode Continued Operation may cause damage to system Consult dealer for problem rectification PLEASE NOTE When Winter Mode switch is On Unit will operate similar to above except Display will fluctuate around 85 Refer Winter Mode page 8 OPERATION OF CHLOROMATIC ESC SYSTEM The Chloromatic ESC system ope...

Страница 7: ... will be 4 hours If the System Control is set to 60 the Cell will operate for 3 hours total over the 5 hour filtration cycle When the System Control is set to MIN the Cell will be OFF for the duration of the filtration cycle When the System Control is set to MAX the Cell will be ON for the duration of the filtration cycle The System Control is graduated in steps of 10 from MIN OFF to MAX ON During...

Страница 8: ...raws less than 80 of maximum current To keep a failed Cell in operation Winter Mode can be used along with extra salt There will come a time when the Cell will not respond to either extra salt or Winter Mode It will then need to be replaced Please note that the Low Salinity Indicator is not like T D S meters which are temperature compensated Scientific Instruments The accuracy will be within 500pp...

Страница 9: ...ights Please Note Only one light can be connected to each light transformer If more than one light is required please refer to your Chloromatic dealer If your unit is fitted with the multi voltage light transformer please ensure it is wired as follows CONNECTION OF LIGHT TRANSFORMER NOTE WIRES FROM LIGHT ARE NOT COLOUR CODED WHITE CONNECT LIGHT WIRES TO VOLTAGE 22V RED WHITE BROWN 12V 12V RED WHIT...

Страница 10: ...viously more in summer The intervals between cleaning could get longer to the point where cleaning is only necessary a few times each year One exception is the use of bore water or ground water in which case cleaning may always need to be as frequent as once a week Life of Chloromatic electrolytic cells vary substantially from one installation to another due to variations in operating time water q...

Страница 11: ...is no water flow Chloromatic Units are also fitted with a Thermal Cut Out to prevent overheating If the temperature rises too high power is automatically disconnected The Unit will resume operation when it cools down DAY TO DAY OPERATION Four Prime rules must be observed if your unit is to give the best possible service 1 STABILISER The importance of pool stabiliser cannot be over emphasised It is...

Страница 12: ... exceed 7000 ppm however no problems will result if this occurs Chloromatic ESR Series chlorinators can be operated in Sea Water Please note ESC Systems salt level must not exceed 6000ppm Consult your local Chloromatic Dealer for more information Salt is the essential element by which your Unit operates Not enough salt means not enough chlorine this simple rule governs the total operation of your ...

Страница 13: ...r the running times can be reduced slightly or the System Control can be turned anti clockwise Test your chlorine level again the following morning at around the same time If your chlorine level is still high repeat the above process until the correct level is attained SUPER CHLORINATION Periodically especially during extremely hot conditions it may be necessary to boost the amount of chlorine in ...

Страница 14: ...ite and the cost of operating the vehicle This fee will not apply if the Unit is returned to the Distributor in your State for repairs If an authorised technician is required to service your Unit and it is found that such services are not covered by warranty labour charges will apply Refer back page of this manual for list of warranty repair agents Monarch Industries strives to reduce or eliminate...

Страница 15: ...6 Chlorinator 3 amp fuse blown 7 Dirty Cell 8 Filter needs backwashing 9 Gas Sensor not connected 10 Running times incorrect 11 Main house fuse blown 12 Pump motor faulty Low Chlorine Production Check for 1 Dirty Cell clean if required 2 Filter needs backwashing 3 Display not at correct production level Cell failing 4 Winter Mode turned On 5 Pool stabiliser too low 6 pH too high 7 Salt level too l...

Страница 16: ...Please note this page has deliberately been left blank ...

Отзывы: