Electrical Systems - House ---
Section 8
The Executive 2005
357
Set 24 hr Start Volts DC -
Starts the generator if the voltage drops below the setting for a consec-
utive 24 hour period. For example: If the voltage is set for 12.5 Volts DC, and house battery voltage
drops below 12.5 Volts for a continuous 24 hour period, the generator will start. This setting is helpful
when storing the motorhome.
CAUTION:
It could be several days before the generator starts from the 24 hour voltage setting.
Do not use this setting when storing the motorhome inside a storage building. Do not
park the motorhome near dry grass.
Set 2 hr start Volts DC -
Starts the generator if the voltage drops below the setting for a consecu-
tive two hour period. For example: If the voltage is set for 12.0 Volts DC and house battery voltage
drops below 12.0 Volts for a continuous two hour period the generator will start. This voltage setting
is usually lower than the 24 hr start voltage setting. Primarily used when dry camping. An example
would be a light load on the house batteries over time. Voltage drops at relatively steady rate until
obtaining the preset voltage for two continuous hours.
Set 15 min start Volts DC -
Same operating principle as the previous two menu items. This voltage
setting is used when applying heavy loads to the house batteries. An example: Using many lights and
the inverter to watch the television and operating the microwave. These types of loads rapidly deplete
battery reserves. Battery voltage drops quickly when applying heavy loads to the house batteries.
Read 30 sec LBCO start VDC -
Used with the menu item
Set Low Battery Cut Off VDC
under
menu heading number “
9 Inverter Setup
.” If house battery voltage drops to this point, the inverter
waits 30 seconds before starting the generator.
NOTE:
This start setting overrides quiet time.
NOTE:
The generator will operate until the bulk and absorption cycles are complete if the gener-
ator started from one of the low battery settings.
Set Exercise period -
Starts the generator regardless of any other setting. Periodically starts the
generator for maintenance reasons. The generator should be operated at least every 30 days to lubri-
cate the internal engine components.
Set Maximum run time h:m -
Displays an error message if the generator operates longer than the
time period set. This is only a message. To cancel the message return to heading number “
2 Generator
Mode
.” Use the
green
button to scroll to
Off
. Setting the time and minute to
00:00
defeats this func-
tion.
Gen Starting Details:
11. Use the down arrow on the
Menu Headings
button to scroll
to menu heading number
13
,
Gen Starting Details
.
Содержание Executive 2005
Страница 14: ......
Страница 16: ......
Страница 30: ...Section 1 General Information The Executive 2005 30 NOTES...
Страница 32: ......
Страница 34: ......
Страница 92: ...Section 2 Driving Safety The Executive 2005 92 Weight Label 100179D...
Страница 98: ...Section 2 Driving Safety The Executive 2005 98 020254...
Страница 101: ...Driving Safety Section 2 The Executive 2005 101 020263 WEIGHT RECORD SHEET 020262...
Страница 102: ...Section 2 Driving Safety The Executive 2005 102 WEIGHT RECORD SHEET 020262...
Страница 103: ...Driving Safety Section 2 The Executive 2005 103 010763d 010689d VIEWS Front Rear...
Страница 104: ...Section 2 Driving Safety The Executive 2005 104 010687e 010688c Roadside Curbside...
Страница 119: ...Driving Safety Section 2 The Executive 2005 119 NOTES...
Страница 120: ...NOTES 120 The Executive 2005 Section 2 Driving Safety...
Страница 122: ......
Страница 132: ...Section 3 Exterior Interior Care The Executive 2005 132 Fabric Specifications Charts...
Страница 133: ...Exterior Interior Care Section 3 The Executive 2005 133...
Страница 134: ...Section 3 Exterior Interior Care The Executive 2005 134...
Страница 135: ...Exterior Interior Care Section 3 The Executive 2005 135...
Страница 136: ...Section 3 Exterior Interior Care The Executive 2005 136 Ralph Lauren Fabrics Optional Package...
Страница 137: ...Exterior Interior Care Section 3 The Executive 2005 137...
Страница 138: ...Section 3 Exterior Interior Care The Executive 2005 138...
Страница 164: ...Section 3 Exterior Interior Care The Executive 2005 164 NOTES...
Страница 166: ......
Страница 204: ...Section 4 Appliances The Executive 2005 204 NOTES...
Страница 206: ......
Страница 264: ...Section 5 Equipment The Executive 2005 264 NOTES...
Страница 266: ......
Страница 299: ...Water Systems Section 6 The Executive 2005 299 TYPICAL WATER BAY 040496c...
Страница 300: ...Section 6 Water Systems The Executive 2005 300 040487m WATER SYSTEMS DIAGRAM Typical Water System Layout...
Страница 301: ...Water Systems Section 6 The Executive 2005 301 NOTES...
Страница 302: ...Section 6 Water Systems The Executive 2005 302 NOTES...
Страница 304: ......
Страница 321: ...LP Gas Systems Section 7 The Executive 2005 321 NOTES...
Страница 322: ...Section 7 LP Gas Systems The Executive 2005 322 NOTES...
Страница 324: ......
Страница 380: ...Section 8 Electrical Systems House The Executive 2005 380 Wiring Systems Interfaced...
Страница 381: ...Electrical Systems House Section 8 The Executive 2005 381 NOTES...
Страница 382: ...Section 8 Electrical Systems House The Executive 2005 382 NOTES...
Страница 384: ......
Страница 419: ...Electrical Systems Chassis Section 9 The Executive 2005 419 ENGINE NO START FLOW CHART...
Страница 420: ...Section 9 Electrical Systems Chassis The Executive 2005 420 NOTES...
Страница 422: ......
Страница 523: ...Chassis Information Section 10 The Executive 2005 523 METRIC U S CONVERSION CHART...
Страница 525: ...Chassis Information Section 10 The Executive 2005 525...
Страница 526: ...Section 10 Chassis Information The Executive 2005 526...
Страница 527: ...Chassis Information Section 10 The Executive 2005 527...
Страница 529: ...The Executive 2005 Index...
Страница 530: ......
Страница 538: ...Index The Executive 2005 538 NOTES...