Electrical Systems - Chassis ---
Section 9
Cayman 2005
313
Reduced Cooling:
1. Coolant valve not operating correctly.
2. Air passages are obstructed.
3. Loose or worn drive belt.
4. Check blower and select switch.
5. Thermostat control valve is faulty.
6. Expansion valve is faulty.
7. Compressor is faulty.
8. Low refrigerant charge.
Blower Does Not Operate or Runs Slow:
1. Check fuses.
2. Check for loose or corroded connection.
3. Check wiring.
4. Check to ensure ignition switch is “
ON
.”
5. Check blower and select switch.
6. Motor shaft has seized.
7. Blower wheel is out of alignment.
Damper Doors Do Not Operate:
1. Is the vacuum generator being powered and producing a vacuum?
2. Check the vacuum line entering the unit for vacuum.
3. Check that the vacuum solenoid mounted on unit is receiving power from the mode
switch. If operating properly, the vacuum solenoid will feel hot if current is engaging the
solenoid.
4. Check the mode switch.
5. Check wiring.
6. Check for a pinch in the vacuum line leading to the vacuum motor that operates the
damper door in question.
Содержание Cayman 2005
Страница 14: ......
Страница 16: ......
Страница 28: ......
Страница 30: ......
Страница 76: ...Section 2 Driving Safety Cayman 2005 76 100179D Weight Label...
Страница 81: ...Driving Safety Section 2 Cayman 2005 81 020254 Cargo Carrying Capacity Flowchart...
Страница 83: ...Driving Safety Section 2 Cayman 2005 83 020255k Actual Worksheet...
Страница 84: ...Section 2 Driving Safety Cayman 2005 84 Weight Record Sheet...
Страница 85: ...Driving Safety Section 2 Cayman 2005 85...
Страница 86: ...Section 2 Driving Safety Cayman 2005 86 010725 010726c VIEWS Front Rear...
Страница 87: ...Driving Safety Section 2 Cayman 2005 87 010723f 010724e Roadside Curbside...
Страница 95: ...Driving Safety Section 2 Cayman 2005 95 NOTES...
Страница 96: ...Section 2 Driving Safety Cayman 2005 96 NOTES...
Страница 98: ......
Страница 108: ...Section 3 Exterior Interior Care Cayman 2005 108 Fabric Specifications Charts...
Страница 109: ...Exterior Interior Care Section 3 Cayman 2005 109...
Страница 134: ...Section 3 Exterior Interior Care Cayman 2005 134 NOTES...
Страница 136: ......
Страница 165: ...Appliances Section 4 Cayman 2005 165 NOTES...
Страница 166: ...Section 4 Appliances Cayman 2005 166 NOTES...
Страница 168: ......
Страница 203: ...Equipment Section 5 Cayman 2005 203 NOTES...
Страница 204: ...Section 5 Equipment Cayman 2005 204 NOTES...
Страница 206: ......
Страница 229: ...Water Systems Section 6 Cayman 2005 229 WATER SYSTEM DIAGRAM 040487c Typical Layout...
Страница 230: ...Section 6 Water Systems Cayman 2005 230 NOTES...
Страница 232: ......
Страница 250: ...Section 7 LP Gas Systems Cayman 2005 250 NOTES...
Страница 252: ......
Страница 285: ...Electrical Systems House Section 8 Cayman 2005 285 ELECTRICAL LAYOUT TYPICAL 060191H Inverter Converter Optional...
Страница 286: ...Section 8 Electrical Systems House Cayman 2005 286 NOTES...
Страница 288: ......
Страница 292: ...Section 9 Electrical Systems Chassis Cayman 2005 292 080427f 080387C 080388c...
Страница 315: ...Electrical Systems Chassis Section 9 Cayman 2005 315 ENGINE NO START FLOW CHART...
Страница 316: ...Section 9 Electrical Systems Chassis Cayman 2005 316 NOTES...
Страница 318: ......
Страница 376: ...Section 10 Chassis Information Cayman 2005 376 LUBRICATION CHARTS 070166G FRONT...
Страница 382: ...Section 10 Chassis Information Cayman 2005 382 METRIC U S CONVERSION CHART...
Страница 384: ...Section 10 Chassis Information Cayman 2005 384...
Страница 385: ...Chassis Information Section 10 Cayman 2005 385...
Страница 386: ...Section 10 Chassis Information Cayman 2005 386...
Страница 387: ...Chassis Information Section 10 Cayman 2005 387...
Страница 389: ...Cayman 2005 INdex...
Страница 390: ......