WATER TANKS -
Measurements & Calibration
The motorhome is equipped with a monitor panel to aid in man-
aging the storage tanks. The monitor panel will be located in a main
Status Monitor Panel in the hallway area. A second monitor can be
found in the roadside service center. The switch marked
TEST
is a
momentary switch which requires being held down while testing the
level of the storage tanks. Read the scale for the desired storage tank
that is to be monitored. Each scale uses colored lights along with a
corresponding scale reading. The lights and scale indications are as follows:
•
Green
lamps indicate good or normal ranges.
•
Amber
lamps indicate fair or partial ranges.
•
Red
lamps indicate full or empty ranges (depending on the scale), which are
in the critical range.
WATER - POTABLE
City Hook-Up
• Connect a potable water hose to the city/fresh water hook-up located
in the service center on the roadside of motorhome.
• The city water hook-up in the service center has a built in pressure
regulator and one-way check valve. The pressure regulator limits the
water pressure to approximately 45 PSI.
• An additional pressure regulator can be connected to the city water
faucet to regulate the pressure to the potable water hose.
• Turn the city water/tank fill valve to the city water position (as
shown).
• Turn on the water supply.
• The water pump can be either off or on. It will not affect the water
pump to leave it on.
NOTE:
When connecting the motorhome to fresh water be sure to use a hose manu-
factured and labeled for potable water to ensure that the hose will not flavor
the water.
CAUTION:
Some outside water sources develop high water pressure, particularly in
mountainous regions. High water pressure is anything over 55 psi (pounds
per square inch). Excessive water pressure may cause leaks in water lines
and/or damage the water heater. (An additional pressure regulator can be
connected to the city water faucet to regulate the pressure to the potable
water hose.) Excess pressure on a hot day can cause the water hose to swell
and burst.
040436b
030446e
040532b
040532e
Water Pressure Regulator.
Fresh Fill
City
Water
Valve shown in the City Water Position
Содержание Cayman 2005
Страница 14: ......
Страница 16: ......
Страница 28: ......
Страница 30: ......
Страница 76: ...Section 2 Driving Safety Cayman 2005 76 100179D Weight Label...
Страница 81: ...Driving Safety Section 2 Cayman 2005 81 020254 Cargo Carrying Capacity Flowchart...
Страница 83: ...Driving Safety Section 2 Cayman 2005 83 020255k Actual Worksheet...
Страница 84: ...Section 2 Driving Safety Cayman 2005 84 Weight Record Sheet...
Страница 85: ...Driving Safety Section 2 Cayman 2005 85...
Страница 86: ...Section 2 Driving Safety Cayman 2005 86 010725 010726c VIEWS Front Rear...
Страница 87: ...Driving Safety Section 2 Cayman 2005 87 010723f 010724e Roadside Curbside...
Страница 95: ...Driving Safety Section 2 Cayman 2005 95 NOTES...
Страница 96: ...Section 2 Driving Safety Cayman 2005 96 NOTES...
Страница 98: ......
Страница 108: ...Section 3 Exterior Interior Care Cayman 2005 108 Fabric Specifications Charts...
Страница 109: ...Exterior Interior Care Section 3 Cayman 2005 109...
Страница 134: ...Section 3 Exterior Interior Care Cayman 2005 134 NOTES...
Страница 136: ......
Страница 165: ...Appliances Section 4 Cayman 2005 165 NOTES...
Страница 166: ...Section 4 Appliances Cayman 2005 166 NOTES...
Страница 168: ......
Страница 203: ...Equipment Section 5 Cayman 2005 203 NOTES...
Страница 204: ...Section 5 Equipment Cayman 2005 204 NOTES...
Страница 206: ......
Страница 229: ...Water Systems Section 6 Cayman 2005 229 WATER SYSTEM DIAGRAM 040487c Typical Layout...
Страница 230: ...Section 6 Water Systems Cayman 2005 230 NOTES...
Страница 232: ......
Страница 250: ...Section 7 LP Gas Systems Cayman 2005 250 NOTES...
Страница 252: ......
Страница 285: ...Electrical Systems House Section 8 Cayman 2005 285 ELECTRICAL LAYOUT TYPICAL 060191H Inverter Converter Optional...
Страница 286: ...Section 8 Electrical Systems House Cayman 2005 286 NOTES...
Страница 288: ......
Страница 292: ...Section 9 Electrical Systems Chassis Cayman 2005 292 080427f 080387C 080388c...
Страница 315: ...Electrical Systems Chassis Section 9 Cayman 2005 315 ENGINE NO START FLOW CHART...
Страница 316: ...Section 9 Electrical Systems Chassis Cayman 2005 316 NOTES...
Страница 318: ......
Страница 376: ...Section 10 Chassis Information Cayman 2005 376 LUBRICATION CHARTS 070166G FRONT...
Страница 382: ...Section 10 Chassis Information Cayman 2005 382 METRIC U S CONVERSION CHART...
Страница 384: ...Section 10 Chassis Information Cayman 2005 384...
Страница 385: ...Chassis Information Section 10 Cayman 2005 385...
Страница 386: ...Section 10 Chassis Information Cayman 2005 386...
Страница 387: ...Chassis Information Section 10 Cayman 2005 387...
Страница 389: ...Cayman 2005 INdex...
Страница 390: ......