The comfort control operates the HVAC (heating, ventilating and air
conditioning) system. A small wall-mounted thermostat located in the living
room, the comfort control operates all the roof air conditioners functions as
well as the LP-Gas furnace operations. The comfort control uses a liquid
crystal display to inform the operator of its current program status.
There are six different functions of the HVAC system:
OFF
,
FAN
,
COOL
,
HEAT PUMP
,
AUX. HEAT
and
FURNACE
. The repeated pressing of the
MODE
button makes these selections. The
FAN
button controls the roof air
conditioner fan speed. Three speeds are available: low, medium and high. Fan
speed control applies to the roof air conditioner's blower speed only. Selecting
the fan speed
AUTO
adjusts the fan speed automatically, depending on
temperature set point and actual temperature in a selected zone. The roof air
conditioners will use all three blower speeds (low, medium or high) in the
COOL
mode when selecting
AUTO
fan when selecting
AUTO
fan if operat-
ing in
HEAT PUMP
mode, only low or high blower speeds are available.
There are separate operating zones for the motorhome designated
Zone 1
and
Zone 2
. Pressing the zone button toggles the zone selection. The selected zone
number flashes while the other remains steady. Pressing the
UP
or
DOWN
buttons controls the temperature range for any HVAC function.
NOTE: The Comfort Control must be ON to operate any
function of the HVAC system. The Comfort Control must be
in the same mode for all zones to function properly. One zone
cannot be on COOL while the other zone uses FURNACE.
DO NOT attempt to mix the modes for separate zones.
Heating or cooling the motorhome will not be any faster by
selecting a very high or very low temperature setting.
Comfort Control Reset:
Should the comfort control exhibit unusual symptoms or not respond to
commands, it may require a reset. The reset establishes factory defaults.
To reset:
• The Battery Cut-off switch must be on.
• Press and hold
MODE
and
ZONE
buttons simultaneously
while switching the
ON/OFF
switch to ON.
• Five to ten seconds after switching the comfort control
ON. The letters
"FF"
appear. Release the
MODE
and
ZONE
buttons. The comfort control backlighting will
remain illuminated. The factory default settings of 72° F
for
COOL
and 68° F for
FURNACE
are then established.
• Select the MODE to confirm factory default. Set
desired setting in the comfort control using normal
programming procedures.
Appliances
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
DIPLOMAT
4 • 1 1 8
WALL
THERMOSTAT
Содержание 2002 Diplomat
Страница 12: ......
Страница 24: ......
Страница 60: ...Driving Safety DIPLOMAT 2 6 0 VIEWS FRONT VIEWS REAR...
Страница 68: ...Driving Safety DIPLOMAT 2 6 8 NOTES...
Страница 70: ......
Страница 98: ......
Страница 130: ...Appliances DIPLOMAT 4 1 3 0 NOTES...
Страница 132: ......
Страница 168: ......
Страница 186: ...Water Systems DIPLOMAT 6 1 8 6 NOTES...
Страница 188: ......
Страница 200: ...LP Gas Systems DIPLOMAT 7 2 0 0 NOTES...
Страница 202: ......
Страница 232: ...Electrical Systems House DIPLOMAT 8 2 3 2 NOTES...
Страница 234: ......
Страница 262: ...Electrical Systems Chassis DIPLOMAT 9 2 6 2 NOTES...
Страница 264: ......
Страница 312: ...Chassis Information DIPLOMAT 1 0 3 1 2 MAINTENANCE LOG Date Odometer Reading Service By Maintenance Performed...
Страница 313: ...GLOSSARY OF TERMS 315 INDEX 319 SURVEY 323...
Страница 314: ......
Страница 324: ...FOLD CUT ALONG DOTTED LINE FOLD...