Monaco - 134 06 05
4
Technical manual "1303"
2.1 Warning to the user
All the local and national regulations, and
in particular those relating to national and
European standards, must be observed when
installing the appliance.
An incorrectly installed heating appliance can
cause serious accidents
(chimney fires, burning of
plastic insulation materials, in partition walls, etc.).
This stove is exempted by DEFRA for burning wood
logs in UK Smoke Control Areas (SCA). DEFRA
exemption is dependent upon the appliance being
fitted with a mechanical stop to prevent closure of the
secondary air control beyond the 25% open position.
You should check that this stop mechanism is fitted
before installation of the stove and certainly before
using the stove in a SCA to burn wood logs. If the stop
mechanism is fitted then the minimum chimney flue
diameter can be 125 mm but if the stop mechanism
is not fitted then the stove is not exempted and
the minimum chimney flue diameter is 150 mm in
accordance with Approved Document J of the building
regulations.
The insulation of both the appliance and the
exhaust gas pipe has to be reinforced
and done
according to the Standards and the Building Regulations
for safety reasons. The installation must be carried
out according to the Standards and the Building
Regulations. Failure to respect the manufacturer’s
instructions will invalidate the warranty.
The manufacturer’s responsibility shall be limited to
the supply of the appliance.
2.2 Location of the unit
Ventilation :
For satisfactory appliance operation
with a
natural draught
, check that sufficient air
for combustion is available in the room. In houses
equipped with one VMC (controlled mechanical
ventilation), this one aspire and renew the ambient
air ; in this case, the residence is under slight low
pressure and a
non-sealable
external air intake must
be installed in addition to the chimney itself, at least
50cm² in section.
Position of the unit :
For new installations, select
a central position within the house, to provide a
good heat distribution around the building. The heat
distribution towards the other rooms will be made
through the communicating doors. These rooms must
be at low pressure or fitted with
non-adjustable
air registers,
placed so that they cannot be
obstructed
, to encourage circulation of the hot air.
Floor and walls :
make sure there are not combustible
or covered with non combustible material. Otherwise
it must be necessary to install a non combustible
protection.
2. Installation instructions
Figure 3 - Minimum clearances
Figure 2 - Smoke exit on the top