Monaco 134 06 05 Скачать руководство пользователя страница 2

Monaco - 134 06 05 

Technical manual "1303"

Package ......................................................p. 3
General characteristics .................................p. 3

Appliance description ...................................p. 3
Operating principle ......................................p. 3

Warning to the user .....................................p. 4
Location of the unit .....................................p. 4

Mounting the flue collar

 ...............................p. 5

Smoke exit on the top .................................p. 5
Smoke exit at rear .......................................p. 5

Flue ............................................................p. 5
Chimney connector ......................................p. 6
Door closing pressure ..................................p. 6
Pre-utilisation check ....................................p. 7 
Maintenance of the chimney.........................p. 7

FRANCO BELGE congratulates you on your choice.

FRANCO BELGE, guarantees the quality of its appliances and is committed to meet  

its customers’ needs.

FRANCO BELGE, which can boast a 80-year experience in the industry of heating devices,  

uses state-of-the-art technologies

to design and manufacture its whole range of products.

This document contains instructions on how to install your appliance and make full use of  

its functions, both for your comfort and safety.

CONTENTS

Product information

 .................................................................................................................... 

p. 3

Installation instructions

 ...............................................................................................................

p. 4

Instructions for user

 ....................................................................................................................

p. 8

Spare parts

 ..................................................................................................................................

p. 12

Fuel ............................................................p. 9
Instruction for use with wood .......................p. 9
Refuelling procedure ....................................p. 9
Operating procedure 
when using solid mineral fuels  .....................p. 9

De-ashing ...................................................p. 9
Maintenance of the chimney....................... p. 10
Maintenance of the stove ........................... p. 10
Safety advice ............................................ p. 10
Trouble shooting ....................................... p. 11

Содержание 134 06 05

Страница 1: ...scription of the appliance Installation instructions Operating instructions Spare parts Warranty certificate Document n 1303 2 25 10 2012 Technical manual to be saved by the user for future reference...

Страница 2: ...d to meet its customers needs FRANCO BELGE which can boast a 80 year experience in the industry of heating devices uses state of the art technologies to design and manufacture its whole range of produ...

Страница 3: ...under the grate when using smokeless fuels Reference 134 06 05 Nominal heat output kW 5 9 Chimney draft required Pa 12 Hearth dimensions width mm 429 depth mm 240 height mm 225 Log dimensions lenght...

Страница 4: ...ulations for safety reasons The installation must be carried out according to the Standards and the Building Regulations Failure to respect the manufacturer s instructions will invalidate the warranty...

Страница 5: ...ss of any non combustible floor under the hearth The hearth must protrude at least 300 mm in front of the stove and 150 mm each side Hearths are provided to prevent combustion appliances setting fire...

Страница 6: ...st be clean It should be swept to remove soot and dislodge tar deposits The flue must be well insulated If the flue inner wall surfaces are cold a good thermal draw is impossible causing condensation...

Страница 7: ...out the smokes from the exhaust gas pipe The connection pipe and any draught stabiliser must have access for cleaning 2 8 Door closing pressure Figure 7 The closing latch rotates around a pressure scr...

Страница 8: ...elling may occur Persistent fume emission is dangerous and must not be tolerated If fume emission does persist Open doors and windows to ventilate room Let the fire go out and dispose of fuel from the...

Страница 9: ...with the door 5 10 mm ajar After several minutes the flames from the firebed are diminishing add 2 half sized logs and keep the door ajar and the air controls unaltered About 12 minutes from the Start...

Страница 10: ...ppliance must be cleaned regularly together with the connecting pipe and the flue pipe Open the door and remove all deposits in the firebox and clean the removable fire grate Cleaning of the glass doo...

Страница 11: ...y burn small wood sticks bundles carpentry offcuts plywood pallets etc Smokes when lighting up Flue duct is cold Burn paper and kindling wood to increase heat Room is in decompression negative pressur...

Страница 12: ...g plate Y P L E J 2 23 262614 00 Heat shield Y P L E J 1 24 265606 00 Knob Y P L E J 1 25 265608 00 Knob Y P L E J 1 26 270402 00 Air control flap Y P L E J 1 27 270417 00 Air control flap Y P L E J 1...

Страница 13: ...05 Technical manual 1303 13 Figure 9 Stove exploded view 37 5 6 40 21 3 3 26 11 1 30 4 8 10 19 43 42 20 2 24 16 16 34 15 22 9 38 39 6 6 27 33 35 18 5 36 29 28 23 25 32 45 2 31 17 13 46 47 48 7 12 13 1...

Страница 14: ...331116 77 Main door L 1 43 331116 79 Main door J 1 43 331116 EF Main door Y 1 44 332004 Air duct Y P L E J 1 45 352175 RH Top plate P 1 45 352175 RP Top plate E 1 45 352175 77 Top plate L 1 45 352175...

Страница 15: ...Technical manual 1303 15 Notes Monaco 134 06 05...

Страница 16: ...costly vis vis the price of the appliance the decision to replace or repair the appliance will be taken by the vendor Our guarantee is for 2 two years for all appliances with the exception of closed c...

Отзывы: