molex RHT 2251-CC Скачать руководство пользователя страница 4

RHT2251-CC Hand Crimp Tool 

Doc No.  64001-4900 

Release Date: 10-15-04 

UNCONTROLLED COPY

 

Page 4 of 6 

Revision: A 

Revision Date: 10-15-04 

Caution:

 Repetitive use of this tool should be avoided

 

Tool Calibration 

 
A Certificate of Calibration (see last page) was supplied with the tool.  To 
recalibrate this tool, pin gauge measurements should be taken in each 
conductor nest and compared to this chart.  The tool should be lubricated 
prior to recalibration to ensure consistent measurements.  Handle preload is 
factory set to 25-45 LBS. See How to Adjust Tool Preload (See Figure 5) to 
recalibrate. 
 
 
 

Wire Range 

“X” Dimension 

Conductor Crimp 

Nest Color Code 

AWG mm² Mean 

Go 

No 

Go 

Crimp 

Inspection 

Marking 

10 - 12  5.00 – 3.30  .127  .124 

.132 

Yellow 

14 - 16  1.30 - 2.00 

.127  .124 

.132 

 

Warranty 

 
This tool is for electrical terminal crimping purposes only.  This tool is made of the best quality materials.  All vital components are 
long-life tested.  All tools are warranted to be free of manufacturing defects for a period of 30 days.  Should such a defect occur, we 
will repair or exchange the tool free of charge.  This repair or exchange will not be applicable to altered, misused or damaged tools.  
This tool is designed for hand use only.  Any clamping, fixturing, or use of handle extensions voids this warranty.  
 
Hand held crimping tools are intended for low volume, prototyping, or repair requirements only. 
 
 
 
 
 
 
 
 
 
 
 

PIN GAUGE IN 

CONDUCTOR CRIMP 

“ Confining ” Crimp 

Содержание RHT 2251-CC

Страница 1: ...eans of evaluating the mechanical properties of the crimped connections The following charts show the UL specifications for various wire sizes The tensile strength is shown in pounds and indicates the minimum acceptable force to break or separate the terminal from the conductor Wire Size AWG UL 486 A UL 310 16 30 30 14 50 50 12 70 70 10 80 80 UL 310 Quick Disconnects Couplers UL 486 A Terminals Co...

Страница 2: ...color coded nest Make sure the end of the terminal fits into the locator pocket securely and the front edge of the barrel is flush against the front edge of the locator See Figure 1 3 Partially close the tool to hold the terminal in place See Figure 2 4 Insert the properly stripped wire into the terminal barrel See Figure 2 and 3 The wire insulation will stop against the taper of the terminal Cycl...

Страница 3: ...ming lodged in the crimping dies and store the tool in a clean dry area Miscrimps or Jams Should this tool ever become stuck or jammed in a partially closed position Do Not force the handles open or closed The tool will open easily by pressing the ratchet release lever See Figure 5 How To Adjust Tool Preload See Figure 5 Over the life of the tool it may be necessary to adjust tool handle preload f...

Страница 4: ...Conductor Crimp Nest Color Code AWG mm Mean Go No Go Crimp Inspection Marking 10 12 5 00 3 30 127 124 132 o Yellow 14 16 1 30 2 00 127 124 132 o Warranty This tool is for electrical terminal crimping purposes only This tool is made of the best quality materials All vital components are long life tested All tools are warranted to be free of manufacturing defects for a period of 30 days Should such ...

Страница 5: ... REQUIRED FOR REPAIR ONLY MAIN SPRING SHOWN 2 9 PARTS LIST Item Order No Description Quantity 64001 4900 Hand Crimp Tool Fig 6 1 64000 0076 Repair Kit Springs Pins and E Rings 1 2 63810 0000 Handle 1 3 64001 4975 Locator Assembly 1 4 64001 4970 Tooling Kit 1 Tooling Kit Only 5 64001 4802 Conductor Punch 1 6 64001 4801 Conductor Anvil 1 7 64001 4904 Insert Punch 1 8 64001 4911 Insert Anvil 1 9 N A ...

Страница 6: ...he Tips ______________ Actual _____________ Pin Gauge of Conductor Nest Nests or Slug height if the nest is the F Crimp style Range Conductor Nest 1 ____________ Actual ______________ Range Conductor Nest 2 ___N A______ Actual ______________ Range Conductor Nest 3 ___N A______ Actual ______________ Technician ______________ Date of Calibration ______________ Calibration should be done every 5 000 ...

Отзывы: