Certificate of Calibration 

 
 

Tool Order Number_____________________ 
 
Tool Eng. Number______________________ 
 
Tool Revision_________________________ 
 
Serial Number ________________________ 
 
Date of Manufacture____________________ 
 
 
Pin Gauge of Conductor Nest/Nests or Slug height if the nest is the “F” Crimp style. 
 
 
Range Conductor Nest # 1 = ____________-- Actual = ______________ 
 
Range Conductor Nest # 2 = ____________-- Actual = ______________ 
 
Range Conductor Nest # 3 = ____________-- Actual = ______________ 
 
 
Technician ______________ 
 
Date of Calibration ______________ 
 
Calibration should be done every 5,000 cycles or 3 months. 
Tools should be lubricated during this operation. 

 

Molex Application Tooling Group 

1150 E. Diehl Road

 

Naperville, IL  60563 

Tel: (630) 969-4550;  

Fax: (630) 505-0049 

Содержание 64005-0900

Страница 1: ...d or with optional bench adapter 19078 0307 ATBA and foot switch Testing Mechanical The tensile test or pull test is a means of evaluating the mechanical properties of the crimped connections The following charts show the UL specifications for various wire sizes The tensile strength is shown in pounds and indicates the minimum acceptable force to break or separate terminal from the conductor Wire ...

Страница 2: ...SA Stranded or Solid 1 1 UL CSA Stranded or Solid 1 1 UL CSA Stranded or Solid 1 2 UL CSA Stranded or Solid 1 3 UL CSA Stranded or Solid 1 1 UL CSA Stranded or Solid 1 2 UL CSA Stranded or Solid 1 3 UL CSA Stranded or Solid 1 4 UL CSA Stranded or Solid 1 1 UL CSA Stranded or Solid 1 2 UL CSA Stranded or Solid 1 3 UL CSA Stranded or Solid 1 4 UL CSA Stranded or Solid 1 5 UL CSA Wire Combinations fo...

Страница 3: ...Solid 1 3 UL CSA Stranded or Solid 1 4 UL CSA Stranded or Solid 1 5 UL CSA Stranded or Solid 6 UL CSA Stranded or Solid 5 UL CSA Stranded or Solid 4 UL CSA Stranded or Solid 3 UL CSA Stranded or Solid 2 UL CSA Crimping Terminals 1 Hold Air Head crimp tool with the locator facing up Insert the closed end connector in the slot 12 22 Make sure that the shoulder of the connector is resting on the loca...

Страница 4: ...thly will significantly enhance the tool life and ensure a stable calibration 4 When tool is not in use store the tool in a clean dry area Tool Calibration A Certificate of Calibration see last page was supplied with the tool To recalibrate this tool pin gauge measurements should be taken in each conductor nest and compared to this chart The tool should be lubricated prior to recalibration to ensu...

Страница 5: ...ion Quantity 64005 0900 Crimp Tool Head Fig 5 1 64005 0000 Basic Air Tool Head 1 2 64001 0975 Locator Assembly 1 3 64001 0970 Tooling Kit 1 4 64005 0605 Guard 1 5 N A 3MM by 6 Long Roll Pin 2 6 N A M4 by 25 Long Freedrive Pan Head Screw 1 Tooling Kit Only 7 64001 0901 Conductor Punch 1 8 64001 0902 Conductor Anvil 1 The following purchased parts are available from an Industrial supply company such...

Страница 6: ...05 0000 Basic Air Tool Head Fig 6 1 64005 0103 Nose Guard 1 2 64000 0077 Repair Kit Springs Rods Pivots Rings and Washers 1 3 N A M4 by 12LG Freedrive Pan Head Screw 1 4 N A M4 by 30LG Freedrive Pan Head Screw 1 5 N A 3 16 by 3 8 Long Dowel Pin 1 The following purchased parts are available from an Industrial supply company such as MSC 1 800 645 7270 Figure 6 3 4 2 2 2 5 1 4 4 2 4 2 2 2 2 2 ...

Страница 7: ...____________ Pin Gauge of Conductor Nest Nests or Slug height if the nest is the F Crimp style Range Conductor Nest 1 ____________ Actual ______________ Range Conductor Nest 2 ____________ Actual ______________ Range Conductor Nest 3 ____________ Actual ______________ Technician ______________ Date of Calibration ______________ Calibration should be done every 5 000 cycles or 3 months Tools should...