Tool Kit for AviKrimp

 Fully Insulated and-Insulated Quick Disconnect Flags 

Doc No: ATS-6400188HM  Release Date: 04-08-15 

UNCONTROLLED COPY

 

Page 5 of 9 

Revision: B 

Revision Date: 06-17-15 

 

Tool Calibration 

 

A Certificate of Calibration (see last page) was supplied with the tool.  To 
recalibrate this tool, pin gauge measurements should be taken in each 
conductor nest and compared to this chart.  The tool should be 
lubricated prior to recalibration to ensure consistent measurements.  

Handle preload is factory set to 25-45 LBS.  See How to Adjust Tool 
Preload, see Figure 5 to recalibrate. 
 

Nest Color Code 

Wire Range 

“X” Dimension Conductor Crimp 

Crimp Inspection 

Marking 

Mean 

Go

 

No Go

 

AWG 

mm² 

In. 

mm 

In. 

mm 

In. 

mm 

Yellow 

10 - 12  5.00-3.30  .115  2.92  .112  2.84  .118  3.00 

 

Warranty

This tool kit is for electrical terminal crimping purposes only.  This tool kit is made of the best quality materials.  All 
vital components are long life tested.  All tools are warranted to be free of manufacturing defects for a period of 30 
days.  Should such a defect occur, we will repair or exchange the tool kit free of charge.  This repair or exchange 

will not be applicable to altered, misused, or damaged tools. 
 

CAUTION

:  Molex crimp specifications are valid only when used with Molex terminals and tooling. 

 

CAUTIONS

 

1.

 

Manually powered hand tools are intended for low volume or field repair.  This tool is 

NOT

 intended for 

production use.  Repetitive use of this tool should be avoided. 

2.

 

Insulated rubber handles are not protection against electrical shock. 

3.

 

Wear eye protection at all times. 

4.

 

Use only the Molex terminals specified for crimping with this tool. 

 

CAUTION:

 Repetitive use of this tool should be avoided. 

 

Certification 

Molex does not certify or re-certify commercial grade hand tools but rather supplies the following guidelines for 
customers to re-certify hand tools. 

 

 

This tool is qualified to pull force only.  To re-certify, crimp a terminal to a wire, which has been stripped 
12.7mm (1/2”) long, so there is no crimping of the insulation.  Pull the terminal and wire at a rate no faster than 
25mm (1.00”) per minute.  See the Molex web site for the Quality Crimp Handbook for more information on pull 

testing. 

 

When the hand tool is no longer capable of achieving minimum pull force, it should be taken out of service and 
replaced. 

 

This tool is very difficult to disassemble and reassemble.  Customer repair is not recommended. 

PIN GAUGE IN 

CONDUCTOR CRIMP 

 

“ Confining ” Crimp 

X

 

Содержание 64001-8800

Страница 1: ...owered Tool SCOPE Products AviKrimp Fully Insulated and Insulated Quick Disconnect Flags 10 12 AWG Testing Mechanical The tensile test or pull test is a means of evaluating the mechanical properties of the crimped connections The following chart shows the UL specifications for various wire sizes The tensile strength is shown in pounds and indicates the minimum acceptable force to break or separate...

Страница 2: ...olex terminals listed above with this tool Do not crimp hardened objects as damage can occur to the tool or die INSTALLATION To install the Tool Kit into the Power Crimp Head follow the steps below Anvils and Punches Installation 1 Insert the Anvils into the bottom slots of the nest Install the M4 x 10 long BHCS and tighten in place 2 Insert the Punches into the top slots of the nest Install the M...

Страница 3: ...ear the tooling Swing the terminal locator against the crimp tool and turn lock up to lock the locator Terminals may also be loaded easily while locator is up against the crimp tool and locked See Figure 3 and 4 1 Insert the terminal with the barrel into the nest and the square edge of the flag facing out Make sure the back of the flag terminal is against the locator When the locator is against th...

Страница 4: ...erminal for proper crimp location Maintenance It is recommended that each operator of the tool be made aware of and responsible for the following maintenance steps 1 Remove dust moisture and other contaminants with a clean brush or soft lint free cloth 2 Do not use any abrasive materials that could damage the tool 3 Make certain all pins pivot points and bearing surfaces in the tool head are prote...

Страница 5: ...ll not be applicable to altered misused or damaged tools CAUTION Molex crimp specifications are valid only when used with Molex terminals and tooling CAUTIONS 1 Manually powered hand tools are intended for low volume or field repair This tool is NOT intended for production use Repetitive use of this tool should be avoided 2 Insulated rubber handles are not protection against electrical shock 3 Wea...

Страница 6: ...imp Head 11 Applications for the Tool Kit Hand Crimp Tool Battery Powered Tool Figure 10 Figure 11 WARNING NEVER operate service install tool kits or adjust the Power Crimp Head without proper instruction and without first reading and understanding the instructions in the proper Manual or Specification Sheet See Chart above for the correct Manual or Specification Sheet WARNING NEVER install toolin...

Страница 7: ...ision B Revision Date 06 17 15 RATCHET RELEASE SCREW Figure 12 M4 X 8mm LONG BHCS 2 1 3 M4 X 18mm LONG BHCS M4 X 10mm LONG BHCS 2 4 WITH TOOL KIT LOCATOR ONLY HAND TOOL PARTS LIST Item Number Order Number Description Quantity 1 63810 1000 Hand Crimp Frame Long 1 2 64001 8870 Tool Kit with Locator 1 3 63811 4773 Locator Base 1 4 64001 8875 Locator REF ...

Страница 8: ...e Date 04 08 15 UNCONTROLLED COPY Page 8 of 9 Revision B Revision Date 06 17 15 Figure 11 1 2 2 M4 by 8 Long BHCS M4 by 18 Long BHCS M4 by 10 Long BHCS 1 POWER HEAD PARTS LIST Item Order No Engineering No Description Quantity 1 63816 0300 63816 0300 Power Crimp Head 1 2 64001 8870 64003 1570 Tool Kit 1 ...

Страница 9: ...______________ Serial Number ___________________ Date of Manufacture__________________ Handle Load Range at 1 inch from the Tips ______________ Actual _____________ Pin Gauge of Conductor Nest Nests or Slug height if the nest is the F Crimp style Range Conductor Nest ____________ Actual ______________ Technician ______________ Date of Calibration ______________ Calibration should be done every 5 0...

Отзывы: