Hand Crimp Tool Quick Disconnect, Female Crimp Terminals
Doc No: ATS-638279300
Release Date: 12-02-15
UNCONTROLLED COPY
Page 1 of 7
Revision: B
Revision Date: 02-08-21
BELL MOUTH
WIRE
INSULATION
CONTACT GAP
0.00mm - 0.05mm
SEAM
3.75mm
0.20
3.75mm
0.20
CONTACT GAP
1.00mm
.20
BEND
DOWN
TWISTIN
G
ROLLING
BEND
UP
CONDUCTOR
BRUSH
STRIP
LENGTH
CONDUCTOR
CRIMP HEIGHT
CUT-OFF
TAB
INSULATION
CRIMP
Application Tooling Specification
FEATURES
A full cycle ratcheting hand tool ensures complete crimps
Ergonomic soft grip handles for comfortable crimping
A precision user-friendly terminal locator wire stop holds terminals in the proper crimping position
Right- and left-handed applications
This tool is IPC/WHMA-A-620 Class 2 compliant
When crimping to AWG type wires, use tool 63811-1500 or 63811-1600
SCOPE
Products: Mini-Fit Sr. Male and Female Terminals crimped to 5mm
2
and 6mm
2
wire.
Terminal
Series No.
Terminal
Order No. (3)
Wire Size
Insulation Diameter
Strip Length
IPC/WHMA-A-620 (1)
Terminal (2)
mm² Construction
mm
In.
mm
In.
mm
In.
42815
42815-0010
42815-0012
42815-0011
42815-0019
6
37 x 0.45mm
4.00-4.20
.157-.165 3.50-5.30 0.14-0.21 7.50-8.50 0.30-0.36
6
84 x 0.29mm
5
65 x 0.32mm
42817
42817-0010
42817-0012
42817-0110
42817-0112
42817-0011
42817-0019
42817-0111
6
37 x 0.45mm
4.00-4.20
.157-.165 3.50-5.30 0.14-0.21 7.50-8.50 0.30-0.36
6
84 x 0.29mm
5
65 x 0.32mm
(1) To achieve optimum IPC/WHMA-A-620 insulation crimps, use this insulation OD range
(2) Overall insulation OD specification for terminal.
(3) Reeled terminals: When cutting terminal from strip, cut-off tab not to exceed 0.50mm (.020”)
DEFINITION OF TERMS
TYPE 4E
Order Number
63827-9300