Tool Kit for 250 Slip-in Receptacle Terminals
Doc No: ATS-6382575HM Release Date: 05-17-13
UNCONTROLLED COPY
Page 3 of 8
Revision:A
Revision Date: 05-17-13
Figure 4
WIRE IN TERMINAL
JAWS
PARTIALLY
CLOSED
WIRE AGAINST
WIRE STOP
HANDLE
OPEN
LOCATOR
CLOSED
Figure 3
TERMINAL
PUSH HERE TO
OPEN WIRE STOP
Anvils and Punches Installation
1.
Insert the Anvils into the bottom slots of the nest. Install the M4 x 10 long BHCS and tighten in place.
2.
Insert the Punches into the top slots of the nest. Install the M4 x 18 long BHCS and tighten in place. See
Figure 1.
Locator Installation and Removal
Follow the steps below to install or replace the locator. See Figure 2.
To install the locator
1.
Position the locator with the hole over the brass pivot shaft and snap it into place.
To remove the locator
1.
Open the crimp hand tool.
2.
Swing the existing locator open and away from the hand tool.
3.
Firmly press down on the brass pivot shaft with your thumb, while pulling the locator up. Slip the locator off the
top of the brass pivot shaft.
OPERATION
Open the tool by squeezing the handles together, at
the end of the closing stroke, the ratchet mechanism
will release the handles, and the hand tool will
spring open.
Crimping Terminals
1.
Select the desired terminal listed in the
preceding charts.
2.
Some terminals with large insulation grips may
interfere with the crimp tooling when swinging
the locator into position. This terminal must
then be loaded into the locator in the
closed/crimp position. See Figure 3.
3.
Press down on the wire stop on the locator as
shown in Figure1. Insert the proper terminal
into the proper nest opening. Make sure when
choosing the nest opening, it will correspond with the A, B or C profile on the hand tool.
Figure 5
WIRE
INSULATION
PUNCH
CONDUCTOR ANVIL
LOCATOR
INSULATION
ANVIL
WIRES AGAINST
LOCATOR STOP
CONDUCTOR
PUNCH
TERMINAL