Tool Kit for CSP 6.3 Receptacle Terminal
Doc No: ATS-6382558HM Release Date: 08-13-12
UNCONTROLLED COPY
Page 4 of 8
Revision: A
Revision Date: 08-13-12
Figure 4
SWING OPEN
TERMINAL
PUSH HERE TO
OPEN WIRE STOP
LOCATOR
TERMINAL
IN PLACE
Figure 5
WIRE IN TERMINAL
JAWS
PARTIALLY
CLOSED
WIRE AGAINST
WIRE STOP
3.
Swing the terminal locator away from the crimp tool shown in Figure 4.
4.
Press down on the wire stop on the locator and insert the proper terminal into the proper nest opening. Make
sure when choosing the nest opening, it will correspond with the A, B or C profile on the hand tool.
5.
Return the locator to its original position.
6.
Turn the Locator Lock Latch up to lock. Make sure that the terminal is visually centered over the punch.
7.
Insert the proper wire over the terminal.
8.
Gently touch the end of the wire against the wire stop in the locator. See Figures 5 & 6
9.
Compress the terminal by squeezing the tool handles until the ratchet mechanism cycle has been completed.
Release handles to open the jaws.
10.
Remove the crimped terminal from the terminal locator by pressing down on the wire stop and gently pulling on
the wire. The terminal locator can be in either position.
11.
Visually inspect the crimped terminal for proper crimp location.
Note
: The tamper proof ratchet action will not release the tool until it has been fully closed.
For the Battery Power Tool:
1.
Cycle the Battery Power Tool to crimp the terminal to the wire.
2.
Remove the crimped terminal from the terminal locator by pressing down on the wire stop and gently pulling on
the wire. The terminal locator can be in either position.
3.
Visually inspect the crimped terminal for proper crimp location.
Figure 6
WIRE
INSULATION
PUNCH
CONDUCTOR ANVIL
LOCATOR
INSULATION
ANVIL
WIRES AGAINST
WIRE STOP
CONDUCTOR
PUNCH
TERMINAL