Figure 2-6
ADDING CONNECTOR STACKS
2.2.5 Adjusting the Wire Tension
It is necessary to make an adjustment to the wire
stop when changing from one wire size to another.
Refer to Figure 2-5.
1.
Turn the stop screw clockwise (CW) to decrease
the tension or counterclockwise (CCW) to
increase the tension applied to the wire. Adjust
the tension so the wire can be pushed through
the guides, into the connector, and held firmly in
place upon release.
2.3
Operation
1.
Load a stack of connectors in between the
guide blocks as shown in Figure 2-2.
2.
Push the connector stack forward until the first
connector “clicks” into position (there are
detents that prevent the connectors from
backing up).
3.
Load the wires individually by inserting them in
the wire guides then pushing them through the
holes in the connector and up against the stop
(See Figure 2-4).
4.
When the wires are loaded, cycle the press by
pulling forward and down on the press lever.
This will press the two halves of the connector
together terminating the wires and latching the
connector halves together. It will also cut the
connector from the stack.
5.
Return the press lever to the up position.
6.
Remove the connector and wire or cable
assembly from the terminator by pressing
down on the wire release lever to the left of the
wire guides and sliding the assembly out to the
right. (See Figure 2-5.) Reference sheet 4 of
Application Specification #ES-990033-0004 to
determine if termination is correct.
11 / 20