background image

Using PVC glue (not included), attach hard or flexible PVC piping to the two included 

connectors, taking note of the orientation of the intake and discharge and the location of the 

tank. Connection size is 1.5" and hard PVC piping should be 1.5" for inlet and discharge.

Note 1:

 

The intake and discharge piping should be as short as possible. Do not exceed 20 feet for 

either the intake or discharge pipes.

 

Note 2:

 

The unit should not be placed more than six feet above the nominal water level.  

Refer to owner’s manual piping placement and pump restrictions.

Included glue-able connections should be hand tightened only, do not use tools to tighten onto 

the pump or discharge. Ensure all connections are tight before beginning startup steps.

Attach Piping

Startup

NANOBUBBLE GENERATOR  

|

  

Quick Start Guide

Scan to Download 

the Owner’s Manual 

and access warranty 

information for the Lotus 

Nanobubble Generator.

www.moleaer.com

Copyright © 2022 Moleaer. All trademarks stated herein are the property of their 

respective company. All rights reserved. This document is confidential and contains 

proprietary information of Moleaer Inc. Neither this document nor any of the 

information contained herein may be reproduced, redistributed or disclosed under any 

circumstances without the express written permission of Moleaer Inc. Rev. 07-05-22

Please contact Moleaer with any  

questions or concerns: +1.424.558.3567

4

5

4.1

4.2

Hand-tighten any  

loose fittings. 

Open the lid of Lotus  

and open any isolation  

valves between the unit and 

tank on both the inlet and 

discharge pipes

When the pump strainer  

fills with water, tighten the 

pump strainer basket lid by 

turning the lid clockwise. 

Run the unit for a minimum 

of 60 minutes. Adjust the 

oxygen regulator knob to 

meet the desired levels of 

dissolved oxygen.

Remove the pump 

basket lid by turning it 

counterclockwise. With 

flooded suction, the basket 

should fill by gravity.  

Turn the oxygen regulator 

knob to ¼ (1/4 lpm).  Check 

for any leaks inside the 

enclosure at various 

connection points.

Check that water is flowing 

through the pump by 

verifying that the strainer 

basket is filled with water.

Turn the Lotus on by  

pushing the start button. 

5.2

5.1

5.6

5.5

5.3

5.7

5.4

5.8

60 min