3
right inside). Calendar clocks see page 26. Cleaning/Disinfec-
tion We recommend cleaning the mask after each use. Remove
the filter; clean the facepiece with warm water (max. 50°C). If
necessary, use a neutral cleaning agent and an alcohol-based
disinfectant. To clean the valve membrane, remove it from the
holder. To remove the filter, refer to the instruction manual for gas
and particulate filters. Dry the mask thoroughly before storing it.
Storage Keep the 8000 mask sealed in a dry, uncontaminated
environment. Protect it against sunlight and sources of heat. The
name of the wearer and a record of the filter changes can be
noted on the packaging. Exhalation Valve (Spare Part -Set No.
8091) Check the exhalation valve and the valve seat for contam-
ination, deformation, fractures or cracks. If necessary, replace
the valve membrane, every 4 years at the latest. Please note date
of replacement. Inhalation Valve Check the inhalation valve on
the inside of the filter for contamination, deformation, fractures or
cracks. If necessary, replace the filter. Head Straps (Spare Part
-Set No. 8091) Check the head straps for deformation, fractures
or cracks. If necessary, replace the strap. All warranties are void
if the product is not stored, used, maintained and serviced ac-
cording to the instructions provided here or if the product is not
used in accordance with the relevant regulations.
Overview of the various types of masks/filters and their appli-
cation limits
Description/Mask Type
Size
Model
Facepiece size small
S
8001
Facepiece size medium
M
8002
Facepiece size large
L
8003
Table 1
Half-mask Series 8000 with... Protection factor/
Maximum Use Level
P1 R D Particulate Filter
4 x WEL
P2 R D Particulate Filter
10 x WEL
P3 R D Particulate Filter
20 x WEL
Class 1 Gas Filter
10 x WEL or 1000 ppm
(whichever is lower)
Class 2 Gas Filter
10 x WEL or 5000 ppm
(whichever is lower)
WEL = Workplace Exposure Limit Marked R: The filters are reus-
able. Marked D: Filters have passed the optional dolomite clog-
ging test. Better breathing resistance for a longer period. Use
of the filter is described in the instruction manual for gas and
particulate filters “Moldex Series 8000”. Select the appropriate
filter for your application.