5.9 Install Manifold Locator
1. Apply anti-seize compound to socket head cap screws.
2. Install the manifold locator to the manifold and torque the screw to the
specified value. See “11.1 Recommended Torque Settings” on page 11-1.
3.
Verify the height of the manifold locator to the dimension specified on the
General Assembly drawing.
5.10 Install Support Bushings
4. Apply anti-seize compound to the screw.
5-21
© 2020 Mold-Masters (2007) Limited. All Rights Reserved.
ASSEMBLY
FSG2 User Manual
Содержание Fusion G2
Страница 1: ...version 14 User Manual Original Instructions...
Страница 2: ......
Страница 10: ......
Страница 64: ......
Страница 151: ......