INSTALLATION DATA SHEET

R201 and RA201 Series

Carefully  twist  lens  firmly  one  turn  clockwise  to  remove  from  base.  Remove  the  inner  reflector

 

assembly from the base of the unit. Fix base to the required surface, utilising rubber gasket, with 2 x M4 

screws (not supplied). Insert power cable through aperture in base & connect to terminal block on underside of

 

reflector assembly.

 For DC units connect Positive lead to the terminal block marked ‘+’  & Negative lead to terminal block marked 

‘-’. The termination is polarity conscious. 

To Re-assemble, position the reflector assembly in the base noting the position of the three internal mounting 

lugs. Fix the assembly onto the lugs using the 3 x No.4 screws supplied. Replace lens onto base ensuring that 

the base spigot ‘O’ ring is in place. Twist lens one turn anti-clockwise to lock and check that the ‘O’ ring is 

positioned correctly and not caught or snagged.

R401/400 Series

Connection  to  this  type  of  unit  is  either  into  the  three  way  barrier  strip  situated  in  the  base  of  the  unit 

(standard  connection)  or  via  the  M20  side  conduit  entry.  If  M20  is  the  preferred  method  then  the  two 

wires  in  the  barrier  strip  in  the  base  need  to  be  unscrewed  and  freed  from  the  barrier  strip.  Un-screw

 

3xNo.4  screws  that  retain  the  base  plate  &  carefully  remove,  threading  the  wires  through  the

 

aperture. Un-screw the same two wires from the internal terminal block. Carefully drill out the M20 entry &

 

using  the  appropriate  cable  gland,  insert  power  cable  into  unit  connecting  to  the  internal  terminal  block. 

Screw  base  plate  back  into  position.  Fix  base  to  the  required  surface  using  the  supplied  gasket  with

 

3 x M6 Hex set screws (not supplied).

Alarm Stages (Modes of Operation)

The RA series is factory wired for combined operation of the audible and visual modes.

For 3 wire control giving independent operation of either lamp or buzzer the following adjustment is required.

Ensure the supply is disconnected before attempting adjustment.

Insert a 3mm flat blade screwdriver into the inspection

slot of the terminal marked ‘+’ (see picture 1) to 

release the ‘wire grip’ and remove the Blue lead from

the back of the terminal top row. Be careful not to

dislodge the other Red/White/Blue leads, depending on

the model. Re-insert the Blue lead into the rear of the

unused middle terminal of the block (top row). Check security of all the leads. A third wire ‘+’ can

now be connected to this terminal to allow independent use of lamp and buzzer.

General Installation Notes

•  Installation must be carried out in accordance with the latest codes and regulations by a qualified electrician.

•  Ensure power is disconnected prior to installation or maintenance.

•  Environmental exposure conditions during installation should be dry, not moist or wet.

•  The lens of the unit is Polycarbonate Plastic. Do not clean with petroleum based cleaners.

•  For  all  installations,  mount  the  beacon  with  the  lens  above  the  base.  Any  other  mounting  position

 

  will impair the IP rating (Ingress Protection) and shorten the working life of the beacon.

•  Avoid mounting the beacon where it will be subject to excessive vibration.

R201 and RA201 Series

R401/400 Series

‘+’ control of lamp
‘+’ control of buzzer
‘-’ common negative

RA201

Picture 1

LEAD TO 

BUZZER

INSPECTION 

SLOT

TERMINAL BLOCK 

(RA201 CONNECTIONS 

SHOWN, FACTORY SET)