Moffat turbofan EH Series Скачать руководство пользователя страница 28

Replacement Parts List 

26 

241141 

CONTROL PANEL LAMINATED 

241147K-GM-EHT10 

TOUCH CONTROLLER KIT GM EHT10 

025997K 

TEMP PROBE ASSY AIR KIT 

238240K 

TEMP PROBE WATER TANK KIT 

242069 

GASKET TEMP PROBES 

235695 

RELAY SINGLE POLE SINGLE THROW 20A, 24VDC 

235698 

TRANSFORMER 208 - 240 24V, 40VA 

234348 

WATER SOLENOID 90° OUTLET 240V 

 

 

022042 

FAN BLADE 

241013 

MOTOR SHAFT SEAL 

241893 

MOTOR KIT 208 - 240V, HP SERIES 

240402 

THERMAL SWITCH 120°C 

241018K 

DRY ELEMENT KIT - 240V, 1600W (208V, 1200W) 

245296K 

DRY ELEMENT KIT - 208V, 1600W 

241019K 

WET ELEMENT KIT - 208V, 600W 

234078K 

WET ELEMENT KIT - 240V, 600W 

241890 

FLOAT SWITCH KIT - EHT10/HP10T 

241885 

LAMP LENS KIT  (Containing the following:-) 

242092 

GASKET 

021352 

GLASS LENS 

021353 

SUPPORT FRAME 

241895 

LAMPHOLDER G9 ,25W, TAB 77.708 

241119 

LED BULB G9, 230V, 50/60HZ, 2.3W, 4000K 

 

 

241131 

DOOR HINGE KIT EHT10/HP10T 

237741 

DOOR MAGNET 

241045 

DOOR SEAL 

 

 

010723 

CONDENSATE DRAWER 

241149 

DOOR CONDENSATE CHANNEL 

242003 

CASTOR SPACER 

238391 

CASTOR 65mm SWIVEL PU D/BRAKE 

238390 

CASTOR 65mm RIGID PU 

236668 

WATER TANK 

242062 

RACK WA LH 

242063 

RACK WA RH 

230130 

DRAIN COVER 

 

 

237358K 

STANDOFF BRACKET KIT 

234347 

FILTER HEAD KIT (3/8 PUSH-FIT) 

234562 

FILTER CARTRIDGE P124BN 

 

 

When ordering replacement parts, please quote the part number and the description as listed below.  If the part required is not listed 

below, request the part by description and quote model number and serial number which is shown on the Technical Data Plate. 

 

Only  genuine  authorized  replacement  parts  should  be  used  for  the  servicing  and  repair  of  this  Humidified  Staging  

Cabinet cabinet.  The instructions supplied with the parts should be followed when replacing components. 

For further information and servicing instructions, contact your nearest authorized service provider or Turbofan Dealer. 

Содержание turbofan EH Series

Страница 1: ...245286 1 Installation and Operation Manual EHT10 Humidified Holding Cabinet HEH...

Страница 2: ...pares tel 1800 337 963 Customer Service tel 1800 335 315 fax 1800 350 281 CANADA Serve Canada Web www servecanada com E Mail info servecanada com Sales tel 800 551 8795 Toll Free Service tel 800 263 1...

Страница 3: ...old Time Expired Time s Up 10 Cabinet Settings Options End of Shift Cabinet Cool Down Manager Mode Parameters and Settings Flow Chart Selecting Manager Mode 1 Control ON 2 Enter Passcode 3 Manager Scr...

Страница 4: ...ler Date Day Settings Controller Language Selection Not Used for this Application Temperature Units F C Setting Manager Mode Parameters and Settings Reference Table Holding Cabinet General Troubleshoo...

Страница 5: ...answer your question Should you contact your TURBOFAN dealer on any matter concerning this Humidified Holding Cabinet please have the information provided opposite readily available This manual must b...

Страница 6: ...20 240V 50HZ Single Phase L1 N E 2 25kW 9 4A 10 x 1 1 GN 20 x 12 Steam Pan Capacity 10 x Half Size Sheet Pan Capacity 27 8 74mm Water Connection USA Canada GHT All Other Markets BSP Water Supply Conne...

Страница 7: ...eficiencies to the distributor who supplied the appliance 5 Ensure that all the castors are fitted securely 6 Check that the available electrical supply is correct to as shown on the Technical Data Pl...

Страница 8: ...t side panel The EHT10 Humidified Holding Cabinet is supplied with factory fit ted power cord and plug 1 Correctly locate the Humidified Holding Cabinet into its final operating position and lock the...

Страница 9: ...nitial Start Up When pre heating is complete the Humidified Holding Cabinet is ready to use Refer to Item 4 Select Shelf overleaf Press to start using Humidified Holding Cabinet Press to turn OFF cont...

Страница 10: ...ting option required on this screen The display will show the shelf selected and the product selected The colour of the loaded shelf will be the same as the frame around the produced image selected NO...

Страница 11: ...e product of the same kind this should be cooked and ready for loading onto the shelves Tick Button Closes the LAST SHELF screen and alarm Acknowledg es that the appropriate actions have been taken Th...

Страница 12: ...product will display as either on the right side of the shelf or left side depending on which 1 2 Shelf option was selected 1 2 Shelf Load Right or 1 2 Shelf Load Left The colour of the loaded shelf w...

Страница 13: ...ning the following Cool Down screen will display The display will show the current cabinet temperature Open the Cabinet door and allow the Cabinet to cool down When the cabinet temperature reaches the...

Страница 14: ...Manager Mode Holding Cabinet Settings Programming 12 Manual...

Страница 15: ...RAMMING Press to select the recipe to program The following screen will appear The Screen will appear as shown Select the recipe to edit Or Press to create new recipe or Press to delete a recipe The E...

Страница 16: ...lect key The Screen will appear Select and the keypad will be displayed Enter the Hold Time required Hold Time Range 0 8 Hrs Press to confirm Press to cancel SELECT LAST SHELF TIME In the screen selec...

Страница 17: ...Press to confirm changes Press to cancel changes SETTING WATER TANK HUMIDITY TEMPERATURE On the Hold Settings screen select to set the water tank temperature Enter the Water Tank temperature on the ke...

Страница 18: ...m a USB IF NO USB HAS BEEN CONNECTED THE FOLLOWING ON SCREEN WARNING WILL APPEAR PLUG IN A USB DRIVE AND FOLLOW THE ON SCREEN PROMPTS On completion Press to cancel changes Screen will revert to Manage...

Страница 19: ...will be available to manually set remaining time for product Press to Enable Disable manual shelf option HALF SHELF ENABLED DISABLED Allows the option of loading smaller trays of product to half the...

Страница 20: ...Select Copy Images from USB the following warning will appear Follow the On Screen prompts Select Delete Recipe Images the following screen will appear Select Images to Delete These can be deleted in...

Страница 21: ...nfirm setting Autostart Temp Range 60 90 C 140 194 F Press to confirm Press to cancel Press to set Autostart humidity Enter humidity level on keypad and confirm setting Autostart Humidity Range 10 85...

Страница 22: ...cel DATE ENTRY SCREEN To change the Day press the number numeric key pad will display To change the Month press the number numeric key pad will display To change the Year press the number numeric key...

Страница 23: ...temperature for cabinet 65 90 C 140 194 F 80 C 176 F WATER TANK HOLD TEMPERATURE Allows setting of temperature for water tank 10 85 C 50 185 F 70 C 158 F COPY HOLD TIMERS TO USB Pre programmed hold t...

Страница 24: ...or all deleted Manager Screen 5 CHANGE PASSCODE Manager passcode can be changed 0000 9999 4500 AUTO START OPTIONS Autostart Autostart temperature can be pre set in real time Temperature Autostart hum...

Страница 25: ...update installation not completed correctly corrupted on load A Call for service Touch Controller replacement required No beeper sound output from controller A Beeper sound volumes set to OFF in Mana...

Страница 26: ...perature probe fault Open circuit A Probe fault B Probe connection circuit fault A Call for service B Call for service ERROR 8 Water Tank High Temperature Error Call For Service Water tank temperature...

Страница 27: ...Electrical Schematic 25 1600W 240V 1600W 208V...

Страница 28: ...W 4000K 241131 DOOR HINGE KIT EHT10 HP10T 237741 DOOR MAGNET 241045 DOOR SEAL 010723 CONDENSATE DRAWER 241149 DOOR CONDENSATE CHANNEL 242003 CASTOR SPACER 238391 CASTOR 65mm SWIVEL PU D BRAKE 238390 C...

Страница 29: ...See adjacent Update by Service Menu Method Steps 1 2 to check if the Service Mode option is available The controller software can be installed by USB through the Service Mode if the existing software...

Страница 30: ...h the Software Update Notification Instructions This SYSTEM screen can also be used to checked the version of Software operating if required The RECIPE SET shows the Recipe Menu Set installed on the C...

Страница 31: ...e cabinet door and swap these over CABINET BODY 1 Remove four blanking screws covering alternate hinge holes on RH side of cabinet Refit cover screws on opposite side 2 Remove Top Hinge Bracket and Pa...

Страница 32: ...ntally and vertically There should be a nominal gap of 6mm from edge of door to side of control panel 1 To align slacken off the upper and lower hinge plates and correctly align the door 2 Re tighten...

Страница 33: ......

Отзывы: