background image

10

Permanent Connection

In the case of a permanent connection, it is
necessary that you install a double pole switch
between the hob and the electricity supply
(mains), with a minimum gap of 3 mm.
between the switch contacts and of a type
suitable for the required load in compliance
with the current electric regulations.

The switch must not break the yellow and
green earth cable at any point.

Ensure that the hob supply cable
does not come into contact with
surfaces with temperatures higher
than 50 deg. C.

Electrical connections

Any electrical work required to install
this hob should be carried out by a
qualified electrician or competent
person, in accordance with the current
regulations.

THIS HOB MUST BE EARTHED.

The manufacturer declines any liability
should these safety measures not be
observed.

This hob is designed to be connected to a
230 V 

~

 50 Hz AC electrical supply.

Before switching on, make sure the
electricity supply voltage is the same as that
indicated on the hob rating plate. The rating
plate is located on the bottom of the hob. A
copy is attached on the back cover of this
book.

The hob is supplied with a 3 core flexible
supply cable.

The wires in the mains lead are coloured in
accordance with the following code:

Green and Yellow

- Earth

Blue

- Neutral

Brown

- Live

1. Connect the green and yellow (earth)
wire to the terminal which is marked with
the letter 'E' or the earth symbol 

 or

coloured green and yellow. The earth wire
should be about 2 cm longer than the
neutral and live wires.

2. Connect the blue (neutral) wire to the

terminal which is marked with the letter 'N'
or coloured black.

3. Connect the brown (live) wire to the

terminal which is marked with the letter 'L'
or coloured red.

Upon completion there must be no cut, or stray
strands of wire present and the cable clamp
must be secure over the outer sheath.

Min. size
Cable/flex

Cable / flex type

Fuse

  0.75 mm

2

H05 V2V2-F (T90)

 3 A

Supply cable replacement

The cable used to connect the hob to the
electrical supply must comply to the
specifications given below.

Содержание MGH 621

Страница 1: ...e using the appliance Keep this instruction book for future reference and ensure it is passed on to any new owner 1 HobTop 2 Rapid Burner 3 Semi rapid Burners 4 Auxiliary Burner 5 Control knobs 6 Electric Ignition Push Button 1 3 2 4 3 6 5 These instructions are only valid for GB ...

Страница 2: ... cooled Children can also injure themselves by pulling pans or pots off the hob During Use This hob is intended for domestic cooking only It is not designed for commercial or industrial purposes This appliance is not connected to a combustion products evacuation device It must be installed and connected in accordance with current installation regulations Particular attention shall be given to the ...

Страница 3: ...symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be ca...

Страница 4: ...tructed The Burners The burner caps and crowns can be removed forcleaning Washtheburnercapsandcrowns usinghotsoapywater andremovemarkswith a mild paste cleaner A well moistened soap impregnated steel wool pad can be used with caution ifthemarksareparticularlydifficultto remove After cleaning be sure to wipe dry with a soft cloth Operation Hob Burners To light a burner pushtheelectricignitionpushbu...

Страница 5: ...ter cleaning Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown have been placed correctly e g after cleaning Something not working If the appliance is not working correctly please carry out the following checks before contacting your local Service Force Centre IMPORTANT If you call out an engineer to a fault listed below or to repair a...

Страница 6: ...inch 1 2 inch male Rear right hand corner Electric 230 V 50 Hz supply 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Aeration adjustment none APPLIANCE CLASS 3 APPLIANCE CATEGORY II 2H3 APPLIANCE GAS SUPPLY Natural gas G20 2H 20mbar Thishobmustbeinstalledbyqualified personnel to the relevant Brit...

Страница 7: ...50 cm2 is required while if the volume exceeds 11 m3 no air vent is required However if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be lo...

Страница 8: ...houlder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to RC 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thoroug...

Страница 9: ...tion is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections FO 1013 3 FO 0199 Fitting the Hob into the worktop Carry out the building in of the hob as follows 1 put the seals supplied with the hob on the edges of the cut out taking care that the seals me...

Страница 10: ...e electricity supply voltage is the same as that indicated on the hob rating plate The rating plate is located on the bottom of the hob A copy is attached on the back cover of this book The hob is supplied with a 3 core flexible supply cable The wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live 1 Connect the green and yellow e...

Страница 11: ...able or is extinguished follow the procedure below Procedure 1 Re ignite the burner and set to MIN 2 Remove the control knob 3 To adjust use a thin bladed screwdriver and turn the adjustment screw it may be located inside the gas tap shaft or on the body of the gas tap itself according to different models see diagram Adjust the minimum gas flow level until the flame is steady and does not extingui...

Страница 12: ... LPG injectors see Characteristics of gas burners on the next page To adjust the gas rate With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw Upon completion affix the replacement rating plate on the under side of the hob IMPORTANT The replacement conversion of the gas hob should only be undertaken by a competent person Pressure Testing Remove the pan sup...

Страница 13: ... 0 043 0 095 0 031 RATE m3 h NOZZLEREFERENCE 119 Adjust 96 Adjust 70 Adjust 1 100mm NOMINALTHERMAL 2 8 0 65 2 0 0 45 1 0 0 33 POWER kW NOMINAL FLOW 202 47 144 32 72 24 RATE g h NOZZLEREFERENCE 86 40 71 32 50 28 1 100mm NATURAL GAS 20 mbar TYPE OF GAS Characteristics LPG GAS 28 30 37 mbar VALUE 49 92 MJ Kg VALUE 37 78 MJ m 3 Ws 50 7 MJ m 3 Characteristics of gas burners ...

Страница 14: ... a commercial or similar environment plus those which are the subject to rental agreements Products of Moffat manufacture which are not marketed by Moffat EuropeanGuarantee This appliance is guaranteed by Electrolux in each of the countries listed below for the period specified in the appliance guarantee or otherwise by law If you move from one of these countries to another of the countries listed...

Страница 15: ......

Страница 16: ...Grafiche MDM Forlì 35676 2903 07 06 www electrolux com ...