background image

5

 

CHARGER OPERATION 

 
The CHG-50 is an intelligent, 

lithium ion

 battery charger.  Operation is as 

follows: 
 

1.  Battery packs may be charged whenever convenient:

  If a battery 

pack is below 90% charge level, it may be placed on the charger at any 
time to recharge to 100%.  Modtech Corp. lithium ion battery packs 
exhibit no memory effect and need not be completely discharged before 
recharging.  

Battery packs that are already above 90% charge level 

when placed on the charger will not be further charged

.  This is 

normal and intentional operation aimed at maximizing the life of your 
battery packs. 
 

2.  Only acceptable battery pack types will be charged:

  When a 

battery pack is placed on the charger its type is detected automatically.  
Only packs known and acceptable to the CHG-50 will be charged. 
 

3.  Charge temperature is controlled:

  The charger will measure its 

own temperature and the temperature of the battery pack.  Charging 
proceeds only when both temperatures are within acceptable limits.  The 
CHG-50 uses a thermostatically controlled fan.  The fan will be enabled 
and operate at a speed needed to cool the charger.  

Fan speed will 

generally increase as charging progresses

 and the charger warms 

up.  A slight “ticking” sound especially at low fan speeds is normal. 
 

4.  When charging is complete,

 removal of the battery pack and 

unplugging the charger at your earliest convenience are recommended.  
No damage will occur if a pack remains attached to the CHG-50 for an 
indefinite period of time, however. 
 

5.  After unplugging the charger, 

the LED may continue to flash for 10 

seconds.  This is normal and not a cause for concern. 
 

6.  Charging time

 for a fully discharged EM-100 battery pack is 

approximately 2-1/2 hours. 
 

7.  Storing batteries at 40% to 50% charge level

 is good practice to 

maximize battery life.  When preparing to store a pack for an extended 
period of time, use the fuel gauge button to see the pack’s charge level.  
If the pack is above 50% charge level, it may be used for a while to 
decrease the level.  If it is below 40%, it may be placed on the charger.  
The charger will increase the packs charge level by 10% in 
approximately 12 minutes.  Charge accordingly to achieve 40% to 50%.   

8.  Failure indication 

is a dot-dash pattern flashed by the LED.  If the 

failure indication occurs with a different battery pack, the failure may be 
within the charger.  There are no user serviceable parts within the 
charger and it must be returned for inspection and repair if needed. 
 
 

 

MAINTENANCE AND STORAGE 

 

Moisture, extreme heat and extreme cold should be avoided when 
storing (or using) the CHG-50.  Refrain from exposing the charger 
to rain, snow, or moisture of any kind.  When storing the charger, a 
cool, dry location is best.  The charger should be unplugged and 
the battery pack removed prior to storing

 

 
 

 

SPECIFICATIONS 

 
Nominal Input Power 

 

 

115 VAC, 1 A, 60 Hz 

Pack Types Charged 

 

 

Modtech Corp. EM-100 

Nominal Charging Voltage 

 

24 VDC 

Nominal Charging Current 

 

2.4 A 

Minimum Charging Temperature  0 

Maximum Charging Temperature 

45 

Dimensions 

 

 

 

6-1/4” x 3-1/4” x 2-3/4” 

     (159 

83 

70 

mm) 

Weight 

    29 

oz. 

(822 

g) 

 

Содержание CHG-50

Страница 1: ... other equipment that is not specifically and expressly designated for use with this model charger 2 AVOID DANGEROUS CONDITIONS AND ENVIRONMENTS Do not charge battery packs in damp or wet conditions Avoid using the charger in direct exposure to rain or snow Do not use the battery pack or charger in the presence of explosive gases or flammable materials because sparks will be generated whenever a b...

Страница 2: ...conditions damage may occur Avoid allowing charger to become wet or damp Allow damp or wet charger to dry thoroughly before using WARNING READ AND SAVE THESE INSTRUCTIONS FOR FUTURE USE Failure to follow all instructions may result in electrical shock fire equipment damage and or serious personal injury 4 FUNCTIONAL DESCRIPTION TABLE 1 CHARGER LED OPERATION If either the charger or battery pack is...

Страница 3: ... to the CHG 50 for an indefinite period of time however 5 After unplugging the charger the LED may continue to flash for 10 seconds This is normal and not a cause for concern 6 Charging time for a fully discharged EM 100 battery pack is approximately 2 1 2 hours 7 Storing batteries at 40 to 50 charge level is good practice to maximize battery life When preparing to store a pack for an extended per...

Страница 4: ...HG 50 Charger with EM 100 Lithium Ion Battery Pack 7136 Eagle Rd Willoughby OH 44094 9636 Tel 440 942 2133 Fax 440 942 2480 support modtech corp com Copyright 2008 Modtech Corp All rights reserved 8 NOTES ...

Отзывы: