Modern Forms
www.modernforms.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
Modern Forms retains the right to modify the design of our products at any time as part of the company's continuous improvement program. DECEMBER, 2016
6
Junction Box
Caulking
Fig. 4 Sealing
PREPARATION
1. Shut off the power at the circuit breaker and remove existing fixture, including the crossbar.
2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
INSTALLATION
MOUNT ON SWITCH BOX
(Fig. 1)
3. Remove the mounting screw (C1) and waterproof washer (D1) from the fixture.
4. Connect the driver input/output wire to supply wires as shown in
Fig. 3
, making sure that all wire connectors (A1) are secured. If your outlet
box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to
the back plate using the green screw provided. After wires are connected, tuck them carefully inside the switch box.
5. Secure the mounting plate to the switch box using the junction box screw (B1). The side of the mounting plate marked “GND” must face out.
6. Place the fixture over the mounting back plate, and secure it with mounting screw (C1) and water proof washer (D1).
7. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape
Fig. 4
.
OR
MOUNT ON JUNCTION BOX
(Fig. 2)
3. Remove the mounting screw (C1) and waterproof washer (D1) from the fixture.
4. Connect the driver input/output wire to supply wires as shown in
Fig. 3
, making sure that all wire connectors (A1) are secured. If your outlet
box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to
the back plate using the green screw provided. After wires are connected, tuck them carefully inside the junction box.
5. Secure the mounting ring (D1) to the junction box using the junction box screw (B1). Make sure the two holes (spacing 2-3/4”) are
horizontal as shown in
Fig 2
. The side of the mounting plate marked “GND” must face out.
6. Place the mounting plate and the conversion plate (E1) onto the mounting ring (F1), secure them with assembly screw (G1).
7. Place the fixture over the mounting back plate, and secure it with mounting screw (C1) and water proof washer (D1).
8. To prevent moisture from entering the outlet box and causing a short, use clear caulking (i.e. indoor/outdoor silicone sealant) to outline the
outside of fixture back plate where it meets the wall. Leave a space at the bottom to allow moisture to escape
Fig. 4
.
INSTALLATION INSTRUCTION
Sabre- Vanities & Wall Sconces
WS-W81625/WS-W81637
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring