15
FR-W1916-56L
FIG.12
White
White
Red
Black
Green (Ground)
Black (To Fan)
Copper
Ground
Black (From Breaker)
Wall Control
Wall Outlet Box
Remember
to disconnect the power at the circuit breaker.
NOTE:
Wall control is intended for indoor installation only.
You can control your fan with up to 4 wall controls or remotes (including the pre-paired control).
Wall control to wall outlet box electrical connections (
FIG.12
):
1.
Connect the green wire marked “GROUND” from the wall control to the copper wire from the wall outlet box that feeds
back to the circuit breaker – important for proper fan function.
2.
Connect the black wire marked “LINE IN” from the wall control to the black LINE VOLTAGE wire from the wall outlet box
that feeds back to the circuit breaker.
3.
Connect the red wire from the wall control to the black wire from the wall outlet box that feeds up to the fan.
4.
Connect the white wire from the wall control to the white (neutral) wire from the wall outlet box.