Partial Recess Installation
NOTE: A dedicated 20 Amp (or higher), 2-pole (for 10,000 BTU
’s) breaker is
required.
FINISHED OPENING FRAMING DIMENSIONS
Model Number
A
B
C
(Partial Recessed)
OR52-MULTI
50-15/16"
(1294mm)
24-9/16"
(624mm)
2-5/8" min.
(67mm min.)
OR60-MULTI
59-7/16"
(1510mm)
24-9/16"
(624mm)
2-5/8" min.
(67mm min.)
OR76-MULTI
75-3/16"
(1910mm)
24-9/16"
(624mm)
2-5/8" min.
(67mm min.)
OR100-MULTI
99-1/2"
(2527mm)
24-9/16"
(624mm)
2-5/8" min.
(67mm min.)
OR120-MULTI
123-13/16"
(3145mm)
24-9/16"
(624mm)
2-5/8" min.
(67mm min.)
•
Prepare the finished
opening according to the “Finished Opening Framing Dimensions” chart for
partial recessed. Ensure an appropriate dedicated circuit is provided at the top right of the framed
opening.
•
Remove the front glass. See “Glass Removal/Installation”.
•
Install the “L” Metal Nailing Flanges to both the top and bottom of the fireplace (Fig. 3-1).
Quantities of “L” Metal Nailing Flanges will change depending on fireplace size ordered. Note that
the location of the “L” bracket will change for partial installation.
Due to different materials used on different walls, it is highly recommended for
you to consult with your local builder before you install this electric fireplace.