16 / 20
GAS COMPONENT CONNECTION CHECKS
Thermocouple
5mm /
0.196”
Igniter Pin
3. Make sure that the igniter pin and thermocouple are correctly positioned.
- The igniter pin should be pointed straight to the thermocouple.
-
The thermocouple should be positioned 5mm / 0.196” away from the burner tube.
Thermocouple
Wire
Valve
Thermocouple Wire
Igniter Box
4. Make sure that the thermocouple wire is correctly positioned. The thermocouple
wire should be in line with the valve.
Wire should
be in line
with valve
Valve
Содержание OFG113-LP
Страница 8: ...8 20 PARTS LIST 1 Fire Table 1 2 LP Regulator and Hose 1 3 Lava Rock 1 ...
Страница 18: ...18 20 TROUBLESHOOTING Orifice is located in this connection Ports ...