15 / 20
GAS COMPONENT CONNECTION CHECKS
If the burner will not light or stay lit, please perform the following checks.
1. Make sure the electrode wire is correctly connected. Both electrode wires must be fully inserted
into the igniter box.
Igniter Box
2. Make sure that the pilot housing is unobstructed.
Clear any debris on top of the pilot housing and make sure there is no debris between the igniter
pin, thermocouple and the burner tube.
CORRECT
INCORRECT
the inner
side
Valve
Thermocouple
Wire
Igniter Box