background image

 

3

 

 

 

 

 

 

     

 

 

General Remark  
 

The  installation  and  maintenance  has  to  be  done  by  qualified 
professionals  or  authorized  technicians  of 

MODENA

MODENA

  is  not 

responsible  for  any  damage  or  malfunction  caused  by  wrong 

installation  or  the  failure  of  following  instructions  that  are  included  in 
this  manual  book.  For  more  information  regarding  to  installation  and 
maintenance guidelines in details, please refer to below chapters. 

 

Caution 
 

Before  installing  this  electric  storage  water  heater,  check  and  ensure 
that  the  power  socket  is  properly  functional  and  reliably  grounded. 
Otherwise, the electrical storage water heater cannot be installed and 

used.  Do  not  use  an  extension  cord  if  there  is  a  problem  with  the 
power  socket.  Incorrect  installation  and  use  of  this  water  heater  may 
result in serious injuries and loss of property. 

 

Special Caution 
 

 

If  the  supply  cord  is  damaged,  it  must  be  replaced  by 

MODENA

 

technicians, 

MODENA

 service agent or similarly qualified persons in 

order to avoid a hazard. 

 

The power socket must be earthed  (grounded) reliably. The rated 

current  of  the  socket  should  not  be  lower  than  16A.  The  power 
socket and the power plug should be kept dry to prevent electrical 

leakage. 

 

The  installation  height  of  the  power  socket  should  not  be  lower 

than 1.8 m. 

 

The  wall  in  which  the  electrical  storage  water  heater  is  installed 

should be able to bear the twice bigger load than the weight of this 
water  heater  filled  fully  with  water  without  distortion  and  cracks. 
Otherwise, other strengthening measures should be adopted. 

 

PART 1: IMPORTANT SAFETY INFORMATION 

Содержание Disteso Series

Страница 1: ...User Manual Book Electric Storage Water Heater Tondo Series ES 30VD ES 50VD ES 80VD ES 100VD Disteso Series ES 30HD ES 50HD ES 80HD ES 100HD ...

Страница 2: ... Use 11 Operating Procedure 11 Operating the Water Heater 12 Function Introduction 13 Product Features 13 Part 5 Maintenance 13 General Instruction 13 Tank Cleaning 15 Savety Valve Cleaning 15 Magnesium Anode 15 Heating Element 16 Part 6 Troubleshooting 15 Part 7 Disposal of Used Product 17 Part 8 Specification 18 Appendix Wiring Diagram 20 This manual book explains everything you need to know abo...

Страница 3: ...a problem with the power socket Incorrect installation and use of this water heater may result in serious injuries and loss of property Special Caution If the supply cord is damaged it must be replaced by MODENA technicians MODENA service agent or similarly qualified persons in order to avoid a hazard The power socket must be earthed grounded reliably The rated current of the socket should not be ...

Страница 4: ...il it has been filled fully with water When filling the water at least one of the outlet valves of the water heater must be opened to exhaust the air This valve can be closed after the water heater has been filled fully with water This appliance water heater is not intended to be used by persons with special needs for their physical sensory or mental capabilities or lack of experience and knowledg...

Страница 5: ...damaged please contact MODENA Customer Care for repair In order to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must be not supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by the utility For the correct operation of the appliance it is necessary to pay attention that the maximum inlet...

Страница 6: ...Rated Volume 30 L 50 L 80 L 100 L Rated Voltage 220 240 Rated Power 1200 W 1200 W 1200 W 1500 W Rated Pressure 0 8 MPa Rated Frequency 50Hz Rated Water Temperature 75 o C Heating Efficiency 90 Water proof Degree IPX4 Structure Mode Hermetically Closed Type Water Storage Style Picture 2 Picture 3 PART 2 PRODUCT INTRODUCTION Picture 4 Water Outlet Safety Valve Opened Water Drainage Valve Position Ha...

Страница 7: ...ld Water Inlet Temperature Display Temperature Controller Knob Power Controller Knob Power Cord Machine Body Cold Water Inlet Temperature Display Hot Water Outlet Hot Water Outlet Cold Water Inlet Power Controller Knob The features and product specifications depend on the product type Temperature Controller Knob ...

Страница 8: ...th is approximately 45 mm Use the anchor fastener bolt that provided along with this appliance for securing the bracket firmly in the wall see Picture 6 Align the slots on the back of the water heater with the projections of the bracket and then mount the water heater on the bracket Thereafter slide the water heater gently towards the bottom side of the bracket to be locked The power supply must h...

Страница 9: ...n of each used pipe is G1 2 BSP The maximum and minimum pressures of the water inlet should use Pa Bar as the unit Connect the pressure relief valve to this water heater on its water inlet In order to avoid leakage when connecting the plumbing the rubber seal gaskets that provided with this water heater must be added at the end of the threads to ensure the connection is leak proof see Picture 8 Pi...

Страница 10: ...Gasket Pressure Relief Safety Valve Cold Water Inlet Pipe Copper Nut for Water Inlet Shower Hot Water Outlet Pipe Nut for Hot Water Outlet Handle for Mixing Water Valve Rubber Gasket Pressure Relief Hole Machine Body Hot Water Outlet Pipe Triple Connection Pipe Basin Water pool Pressure Relief Pipe Pressure Relief Safety Valve Shower Water Inlet Pipe Water Inlet Valve ...

Страница 11: ... Press the testing button the indicator light on the power plug should be off and the reset button should bounce up then push down the reset button the indicator light will turns on to verify that the leakage protection works well see Picture 10 If the reset button cannot be pressed during the use the leakage protection device ELCB might be error or fails to work If the reset button is pressed dow...

Страница 12: ...ition I II or III and the water heating process starts The water heater needs to be turned on for a certain period of time to reach the desired set temperature During the heating process it is normal to see the slight drip at the safety valve Please do not cover the hole of the safety valve outlet Connect the outlet hole to a drainage pipe The water may drip from the drainage pipe of the safety va...

Страница 13: ...tched off General Instruction Check the power plug and the power socket as often as possible Electrical contact must be secured and also must be provided proper grounding The power plug and the power socket must not heat excessively If the water heater is not used for a long time especially in regions with low air temperature below 0 o C it is necessary to drain the water from the heating tank to ...

Страница 14: ...e of water in the tank If the water heater is connected to the power supply electricity but the water is not heated and the indicator does not light up then the thermal switch was off or not switched on To reset the water heater to the normal operating condition it is necessary to 1 De energize the water heater Remove the plate of the front cover upside 2 Press the button that is located at the ce...

Страница 15: ...ve the safety valve then clean and wash it 2 Check if the parts of the valve are still able to move well 3 After cleaning the valve install the safety valve back to its position by first giving the seal tape around the end of valve 4 Fill the water heater with water after the pipes are refitted Magnesium Anode Magnesium Anodes functions to neutralize the corrosive substances in the water and will ...

Страница 16: ...is off 1 Power source is not connected or badly connected 2 Indicator light is damaged 3 Overheating sensor is activated Contact MODENA Customer Care for repair No water flows out from hot water outlet 1 Water supply is cut off 2 Water pressure is too low 3 Water Inlet valve is not opened 1 Wait for the restoration of water supply 2 Use the water heater again when the water pressure is increased 3...

Страница 17: ... on the product or in its packaging indicates that this product must not be treated as household waste Instead it should be taken to the appropriate waste collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be cause...

Страница 18: ...Pressure 0 015 0 8 MPa Water Pipe Diameter 0 5 Inch Temperature Max 75o C Insulation Material PUF Polyurethane Product Dimension 410 x 410 x 1110 mm 410 x 410 x 920 mm 410 x 410 x 675 mm 340 x 340 x 620 mm Product Weight 29 2 kg 25 kg 17 5 kg 14 kg Specifications of this appliance may change without notice to improve the quality of the product Pictures in this manual are schematic and may not matc...

Страница 19: ...1500 W Water Pressure 0 015 0 8 MPa Water Pipe Diameter 0 5 Inci Temperature Max 75o C Insulation Material PUF Polyurethane Product Dimension 1095 x 410 x 410 mm 918 x 410 x 410 mm 910 x 340 x 340 mm 650 x 340 x 340 mm Product Weight 31 kg 25 kg 19 kg 13 6 kg Specifications of this appliance may change without notice to improve the quality of the product Pictures in this manual are schematic and m...

Страница 20: ...20 ES XXHD ES XXVD APPENDIX WIRING DIAGRAM Picture 13 Thermostat Power Input Switch Thermostat Power Input Switch Thermal Cut out Thermal Cut out Transformer Transformer Display Display ...

Страница 21: ...12 20 ...