11
Operating Procedure
Check all the piping connection to avoid the leakage before turning
on this electric storage water heater.
Open one of the outlet valves of the water heater, then, open the
inlet valve .to get the water heater filled with water.
When the water flows out of the outlet pipe, it implies that the
water heater has been filled fully with water, and the outlet valve
can be closed.
Make sure that the tank is fully filled up with water; otherwise, it
will damage the heating elements.
During normal operation, the water inlet valve should always kept
open.
Insert the power plug into the power socket and check the
reliability of the leakage protection device (ELCB). Press the testing
button, the indicator light on the power plug should be off, and the
reset button should bounce up; then push down the reset button,
the indicator light will turns on to verify that the leakage protection
works well (see Picture 10). If the reset button cannot be pressed
during the use, the leakage protection device (ELCB) might be
error or fails to work; If the reset button is pressed down and
bounce up again, then it shows that the power circuit leaks or the
the power supply is disconnected.
NOTE
Please be sure to use the accessories provided by MODENA to
install this electric storage water heater. This electric storage
water heater cannot be hung on the bracket until it has been
confirmed to be firm and reliable. Otherwise, this water heater may
drop off from the wall, resulting to its damage, even serious
accidents of injury to the user.