Modena AP 6034 SKY Скачать руководство пользователя страница 8

 

  English   8 

 

 

Long  press  WIFI  button  for  5  seconds  to  turn  WIFI 
mode.  WIFI  button  will  flash  rapidly  and  ready  for 
network  connect.  WIFI  button  will  stop  flashing  and 
the light will keep on if it successfully connect to the 
network.  Long  press  the  WIFI  button  again  to  reset 
the WIFI function. 

 

Rotate the knob until intelligent mode indicator light 
on  to  enter  intelligent  mode.  The  fan  speed  will 
adjust automatically based on real time PM2.5 value. 
Rotate the knob again to leave the intelligent mode. 

 

Rotate the knob to set the fan speed, clockwise for 
low to high and vice versa. The fan speed indicator 
will change along with the block indicator.  

 

The corresonding light will turn on based on different 
time setting. 
1h for 1 hour, 2h for 2hours, 1h 2h for 3hours, 4h for 
4 hours, 1h 4h for 5 hours, 2h 4h for 6 hours, dan 1h 
2h 4h for 7 hours. 

 

The  corresonding  light  will  turn  on  based  on  the 
activated function. 

 

Display real-time PM2.5 value 

 

Display real-time room temperature 

 

Display real-time room relative humidity. 

 

Each  block  represents  500  hours  using  time.  It  will 
reduce  gradually  along  with  the  filter  lifetime 
remaining. 

 

Air Quality Indicator 

Air Quality Status 

Excellent  

Good 

Poor 

Indicator Light Color 

Green 

Blue 

Red 

Air Quality Value 

 

75 μg/m3

 

75 

 

150 μg/m3

 

150 μg/m3

 

Wind Speed 

Low 

Medium 

High 

Содержание AP 6034 SKY

Страница 1: ...User Manual Book Air Purifier Sofisticato Series AP 6034 SKY ...

Страница 2: ...5 Control Panel and Display 6 Part 3 How to Use 7 Panel and Display Instruction 7 Air Quality Indicator 8 Part 4 Maintenance 9 Part 5 Troubleshooting 10 Part 6 Specification 11 Appendix Wiring Diagram 12 This manual book explains everything you need to know about your new product Please contact our Customer Care should you need further assistance through www modena com ...

Страница 3: ...t permitted by manufacturer otherwise warranty will be terminated if the device is breakdown in that case Prohibitions 1 Do not put your hand and foreign matter into the air inlet and air outlet 2 Do not unplug the power with wet hands 3 Do not use the device at the place where full of hydogen natural gas dimethylmethane and other flammable gas 4 Do not use the device if power cord or plug is dama...

Страница 4: ... hands hold on both sides of the buckle to move it If user hold the air outlet it is possible to make the air outlet or the host device fall off which can cause injury 2 This device is not intended to be used by persons with special needs for their physical sensory or mental capabilities or lack of experience and knowledge including children unless they have been given the supervision or instructi...

Страница 5: ...t Components PART 2 PRODUCT INTRODUCTION Air Quality Indicator Light Control Panel Power Button Panel Display Right Buckle Air Intake Negative Ion Generator Air Outlet Network Light Sensor Upper Body Left Buckle Filter ...

Страница 6: ...d Display Power Switch Fan Speed Display Sleep Mode Time Set Display Filter Reset Function Display Timer Setting Child Lock PM 2 5 Status Anion Function Temperature Display WIFI Connect Humidity Display Auto Mode Filter Lifetime ...

Страница 7: ...ong press the filter button until the red light stop flashing and the block will be full again after it These button has two functions Quick tap this button to set the timer 1 tap for 1 hour 2 taps for 2 hours and so on Time can be set until 7 hours To activate the child lock function long press on the button for about 3 seconds This button indicator will turn on and other buttons are not function...

Страница 8: ...r low to high and vice versa The fan speed indicator will change along with the block indicator The corresonding light will turn on based on different time setting 1h for 1 hour 2h for 2hours 1h 2h for 3hours 4h for 4 hours 1h 4h for 5 hours 2h 4h for 6 hours dan 1h 2h 4h for 7 hours The corresonding light will turn on based on the activated function Display real time PM2 5 value Display real time...

Страница 9: ...t cover on the composite filter a vacuum cleaner can be used to clean the dust on its surface to extend filter lifetime Notes Filter lifetime can shorten if being used for certain condition such as in a room where many people smoke Please replace the filter when purify effect is not good anymore Please dispose the used filter as non combustible garbage Filter Replacement Method 1 Power off the dev...

Страница 10: ...l at the air inlet or outlet 3 Clean or replace the filter Dust removal effect is not obvious and air quality does not get better 1 No filter in the device 2 Door or window of the room open frequently 3 The device is put in narrow place or close to barrier around 4 The filter is dirty 1 Install filter into the device 2 Reduce the door or window opening frequency 3 Move device to wider place withou...

Страница 11: ...sor Yes Filter Replacement Indicator Yes Child Lock Yes Rated Voltage 220 V 60 Hz Power 48 W Clean Air Delivery Rate 550 m3 h Coverage Area 50 60 m2 Dimension 380 x 380 x 760 mm Specifications of this appliance may change without notice to improve the quality of the product Pictures in this manual are schematic and may not match your product exactly Values stated on the machine labels or in the do...

Страница 12: ...English 12 APPENDIX WIRING DIAGRAM WIFI Module Control Panel Light Sensor Display Panel Power Board Power Source Bouncing Pin With Male End ...

Страница 13: ...03 21 ...

Отзывы: