General Cautions 
1.

 

Please  check  whether  the  device  is  fine  and  the  components  are 
complete after unboxing the package. 

2.

 

Please  be  sure  to  remove  the  plastic  package  of  the  filter  before 
first time using the device. 

3.

 

Children  and  incapacitated  person  should  use  the  device 
accompanied by their superintendent. 

4.

 

Please unplug the device immediately if accident occurs, and do not 
use the machine under defect condition. 

5.

 

In order to avoid danger, if the supply cord is damaged, it can only 
be change by manufacturer or the qualified maintenance person. 

6.

 

Please  do  not  use  other  components  that  are  not  permitted  by 
manufacturer, otherwise warranty will be terminated if the device is 
breakdown in that case.   

 
 
Prohibitions 
1.

 

Do  not  put  your  hand  and  foreign  matter  into  the  air  inlet  and  air 
outlet. 

2.

 

Do not unplug the power with wet hands. 

3.

 

Do  not  use  the  device  at  the  place  where  full  of  hydogen,  natural 
gas, dimethylmethane, and other flammable gas. 

4.

 

Do not use the device if power cord or plug is damaged, or power 
socket slacked off. 

5.

 

Do not jam the air inlet and air outlet 

6.

 

Do not use the device when using the aerosol bomb or there are oil 
residue, incense smoke, alight flame, and chemical odor in the room. 
And also do not use the device in deep wet place such as shower 
room.  

7.

 

Do not operate the device without filter inside. 

8.

 

Do not wash or re-use the composite filter. 
 
 
 

PART 1: IMPORTANT SAFETY INFORMATION 

Содержание AP 6034 SKY

Страница 1: ...User Manual Book Air Purifier Sofisticato Series AP 6034 SKY ...

Страница 2: ...5 Control Panel and Display 6 Part 3 How to Use 7 Panel and Display Instruction 7 Air Quality Indicator 8 Part 4 Maintenance 9 Part 5 Troubleshooting 10 Part 6 Specification 11 Appendix Wiring Diagram 12 This manual book explains everything you need to know about your new product Please contact our Customer Care should you need further assistance through www modena com ...

Страница 3: ...t permitted by manufacturer otherwise warranty will be terminated if the device is breakdown in that case Prohibitions 1 Do not put your hand and foreign matter into the air inlet and air outlet 2 Do not unplug the power with wet hands 3 Do not use the device at the place where full of hydogen natural gas dimethylmethane and other flammable gas 4 Do not use the device if power cord or plug is dama...

Страница 4: ... hands hold on both sides of the buckle to move it If user hold the air outlet it is possible to make the air outlet or the host device fall off which can cause injury 2 This device is not intended to be used by persons with special needs for their physical sensory or mental capabilities or lack of experience and knowledge including children unless they have been given the supervision or instructi...

Страница 5: ...t Components PART 2 PRODUCT INTRODUCTION Air Quality Indicator Light Control Panel Power Button Panel Display Right Buckle Air Intake Negative Ion Generator Air Outlet Network Light Sensor Upper Body Left Buckle Filter ...

Страница 6: ...d Display Power Switch Fan Speed Display Sleep Mode Time Set Display Filter Reset Function Display Timer Setting Child Lock PM 2 5 Status Anion Function Temperature Display WIFI Connect Humidity Display Auto Mode Filter Lifetime ...

Страница 7: ...ong press the filter button until the red light stop flashing and the block will be full again after it These button has two functions Quick tap this button to set the timer 1 tap for 1 hour 2 taps for 2 hours and so on Time can be set until 7 hours To activate the child lock function long press on the button for about 3 seconds This button indicator will turn on and other buttons are not function...

Страница 8: ...r low to high and vice versa The fan speed indicator will change along with the block indicator The corresonding light will turn on based on different time setting 1h for 1 hour 2h for 2hours 1h 2h for 3hours 4h for 4 hours 1h 4h for 5 hours 2h 4h for 6 hours dan 1h 2h 4h for 7 hours The corresonding light will turn on based on the activated function Display real time PM2 5 value Display real time...

Страница 9: ...t cover on the composite filter a vacuum cleaner can be used to clean the dust on its surface to extend filter lifetime Notes Filter lifetime can shorten if being used for certain condition such as in a room where many people smoke Please replace the filter when purify effect is not good anymore Please dispose the used filter as non combustible garbage Filter Replacement Method 1 Power off the dev...

Страница 10: ...l at the air inlet or outlet 3 Clean or replace the filter Dust removal effect is not obvious and air quality does not get better 1 No filter in the device 2 Door or window of the room open frequently 3 The device is put in narrow place or close to barrier around 4 The filter is dirty 1 Install filter into the device 2 Reduce the door or window opening frequency 3 Move device to wider place withou...

Страница 11: ...sor Yes Filter Replacement Indicator Yes Child Lock Yes Rated Voltage 220 V 60 Hz Power 48 W Clean Air Delivery Rate 550 m3 h Coverage Area 50 60 m2 Dimension 380 x 380 x 760 mm Specifications of this appliance may change without notice to improve the quality of the product Pictures in this manual are schematic and may not match your product exactly Values stated on the machine labels or in the do...

Страница 12: ...English 12 APPENDIX WIRING DIAGRAM WIFI Module Control Panel Light Sensor Display Panel Power Board Power Source Bouncing Pin With Male End ...

Страница 13: ...03 21 ...

Отзывы: