Page 6 of 6
Programming parameters e.g. with the Control Panel SPF-PIC
Preparations for Programming:
To be able to programme the parameters, the Accessory Decoder
WDMiba is required to be connected to a central unit via the SX-
bus cable.
Enter programming mode:
Set the central unit to STOP mode by pressing the “ZE“-key
(ZE aus).
Press the programme button of the Accessory Decoder
WDMiba. The module’s LED activates to indicate program-
ming mode.
Remark: Activate decimal decoding in the Control Panel to facili-
tate decimal conversion.
The current configuration settings are copied to channels (SX
addresses) 0 to 3 of the central unit.
Enter the address of the Accessory Decoder:
Select address 00 in Control Panel.
Enter switching mode by key “Adr“
and enter 0, 0. The current address of
the occupancy decoder is displayed,
e.g. address 80:
Adr ----/-/-=080
000 12345678 aus
Enter new address of this module
e.g. address 34 with keys 2 and 6:
Adr -/---/--=034
000 12345678 aus
Enter operation mode for each output channel:
Select address 01 in Control Panel.
Current settings of all outputs are dis-
played, e.g. timer 2 selected for chan-
nels 3, 4 and 6, all the others use
timer 1:
Adr --//-/--=044
001 12345678 aus
Enter new operation modes
e.g. use timer 2 for outputs 7 and 8 by
pressing keys 7 and 8, all the other
outputs will use timer 1:
Adr ------//=192
001 12345678 aus
Enter timer 1:
Select address 02 in Control Panel.
Current value of timer 1 is displayed,
e.g. bit 4 on means that the time is
0.64 s:
Adr ---/----=008
002 12345678 aus
Enter new dropout delay
Enter value for timer 1 binary, e.g. 8
seconds press keys 3, 6 and 7
Adr --/--//-=100
002 12345678 aus
Enter timer 2:
Select address 03 in Control Panel.
Enter switching mode by key “Adr“
and enter 0, 3. Current value of timer
2 is displayed in binary, e.g. all bits
are on (“/”) equals continuous output
current:
Adr ////////=255
002 12345678 aus
Enter new value for timer 2
Enter value for timer 2 binary, e.g.
0,16 seconds by key 2:
Adr -/------=002
002 12345678 aus
Exit programming mode:
Press the programme button of the occupancy detector or
enable track current by pressing “ZE” at the central unit or
Control Panel. The LED of the occupancy detector will blink
twice for confirmation.
All parameters programmed via the addresses 0 to 3 have been
stored in the registers of the Accessory Decoder WDMiba.
Table of example values for timers
Examples of bit settings for various pulse lengths (in seconds):
Bit
1
2
3
4
5
6
7
8
Value
1
2
4
8
16
32
64
128
0,4
/
-
/
-
-
-
-
-
0,8
-
/
-
/
-
-
-
-
4,0
-
/
-
-
/
/
-
-
16,0
-
-
-
/
-
-
/
/
20,0
-
/
-
/
/
/
/
/
Continuous
/
/
/
/
/
/
/
/
Address Table
Bit:
1
2
3
4
5
6
7
8
Value
1
2
4
8
16
32
64 128
Address
0
-
-
-
-
-
-
-
-
1
/
-
-
-
-
-
-
-
2
-
/
-
-
-
-
-
-
3
/
/
-
-
-
-
-
-
4
-
-
/
-
-
-
-
-
5
/
-
/
-
-
-
-
-
6
-
/
/
-
-
-
-
-
7
/
/
/
-
-
-
-
-
8
-
-
-
/
-
-
-
-
9
/
-
-
/
-
-
-
-
10
-
/
-
/
-
-
-
-
11
/
/
-
/
-
-
-
-
12
-
-
/
/
-
-
-
-
13
/
-
/
/
-
-
-
-
14
-
/
/
/
-
-
-
-
15
/
/
/
/
-
-
-
-
16
-
-
-
-
/
-
-
-
17
/
-
-
-
/
-
-
-
18
-
/
-
-
/
-
-
-
19
/
/
-
-
/
-
-
-
20
-
-
/
-
/
-
-
-
21
/
-
/
-
/
-
-
-
22
-
/
/
-
/
-
-
-
23
/
/
/
-
/
-
-
-
24
-
-
-
/
/
-
-
-
25
/
-
-
/
/
-
-
-
26
-
/
-
/
/
-
-
-
27
/
/
-
/
/
-
-
-
28
-
-
/
/
/
-
-
-
29
/
-
/
/
/
-
-
-
30
-
/
/
/
/
-
-
-
31
/
/
/
/
/
-
-
-
32
-
-
-
-
-
/
-
-
33
/
-
-
-
-
/
-
-
34
-
/
-
-
-
/
-
-
35
/
/
-
-
-
/
-
-
36
-
-
/
-
-
/
-
-
37
/
-
/
-
-
/
-
-
38
-
/
/
-
-
/
-
-
39
/
/
/
-
-
/
-
-
Bit
1
2
3
4
5
6
7
8
Value
1
2
4
8
16
32
64 128
Address
40
-
-
-
/
-
/
-
-
41
/
-
-
/
-
/
-
-
42
-
/
-
/
-
/
-
-
43
/
/
-
/
-
/
-
-
44
-
-
/
/
-
/
-
-
45
/
-
/
/
-
/
-
-
46
-
/
/
/
-
/
-
-
47
/
/
/
/
-
/
-
-
48
-
-
-
-
/
/
-
-
49
/
-
-
-
/
/
-
-
50
-
/
-
-
/
/
-
-
51
/
/
-
-
/
/
-
-
52
-
-
/
-
/
/
-
-
53
/
-
/
-
/
/
-
-
54
-
/
/
-
/
/
-
-
55
/
/
/
-
/
/
-
-
56
-
-
-
/
/
/
-
-
57
/
-
-
/
/
/
-
-
58
-
/
-
/
/
/
-
-
59
/
/
-
/
/
/
-
-
60
-
-
/
/
/
/
-
-
61
/
-
/
/
/
/
-
-
62
-
/
/
/
/
/
-
-
63
/
/
/
/
/
/
-
-
64
-
-
-
-
-
-
/
-
65
/
-
-
-
-
-
/
-
66
-
/
-
-
-
-
/
-
67
/
/
-
-
-
-
/
-
68
-
-
/
-
-
-
/
-
69
/
-
/
-
-
-
/
-
70
-
/
/
-
-
-
/
-
71
/
/
/
-
-
-
/
-
72
-
-
-
/
-
-
/
-
73
/
-
-
/
-
-
/
-
74
-
/
-
/
-
-
/
-
75
/
/
-
/
-
-
/
-
76
-
-
/
/
-
-
/
-
77
/
-
/
/
-
-
/
-
78
-
/
/
/
-
-
/
-
79
/
/
/
/
-
-
/
-
Bit
1
2
3
4
5
6
7
8
Value
1
2
4
8
16
32
64 128
Address
(**) 80
-
-
-
-
/
-
/
-
81
/
-
-
-
/
-
/
-
82
-
/
-
-
/
-
/
-
83
/
/
-
-
/
-
/
-
84
-
-
/
-
/
-
/
-
85
/
-
/
-
/
-
/
-
86
-
/
/
-
/
-
/
-
87
/
/
/
-
/
-
/
-
88
-
-
-
/
/
-
/
-
89
/
-
-
/
/
-
/
-
90
-
/
-
/
/
-
/
-
91
/
/
-
/
/
-
/
-
92
-
-
/
/
/
-
/
-
93
/
-
/
/
/
-
/
-
94
-
/
/
/
/
-
/
-
95
/
/
/
/
/
-
/
-
96
-
-
-
-
-
/
/
-
97
/
-
-
-
-
/
/
-
98
-
/
-
-
-
/
/
-
99
/
/
-
-
-
/
/
-
100
-
-
/
-
-
/
/
-
101
/
-
/
-
-
/
/
-
102
-
/
/
-
-
/
/
-
103
/
/
/
-
-
/
/
-
(*) 104
-
-
-
/
-
/
/
-
(*) 105
/
-
-
/
-
/
/
-
(*) 106
-
/
-
/
-
/
/
-
(*) 107
/
/
-
/
-
/
/
-
(*) 108
-
-
/
/
-
/
/
-
(*) 109
/
-
/
/
-
/
/
-
(*) 110
-
/
/
/
-
/
/
-
(*) 111
/
/
/
/
-
/
/
-
(**) Factory default setting
(*) Those addresses are available with restrictions.
Consult the remarks in the instructions of the central
unit or SX bus extension uses.