modec MC89 Series Скачать руководство пользователя страница 4

 

 

 
 

 

+33 4 75 40 27 15

 

 

Introduction 

This instruction manual must always be available and kept close to where the actuator will 
be used. 
This  document  is  unique  and  is  owned  by  the  company 

modec

.  It  cannot  be  corrected, 

modified    or  duplicated  without  prior  written  agreement.  This  document  should  not  be 
considered a replacement for safety rules set out in the Work Code or in any other legislation 
that applies to the site where the actuator is used. 
It  belongs  to  the  operators  to  make  sure  that  all  security  regulations  applicable  to  both  the 
work site and the Portable Valve Actuator conditions of use are respected. 

modec 

products are conceived and fabricated with the utmost care and attention for the 

safety of both the operator and the equipment. This is certified by the declaration of conformity 
with the relevant clauses in the European directive 2006/42/CE. 
The actuators described in this document may evolve. We reserve the right to modify their 
specifications,  without  prior  notice.  Updates  will  be  available  on  our  website  www. 

modec

.fr.  It  is important  to  refer  to  the  website  before  setting  up  or  using  the  actuator,  and 

before  carrying  out  maintenance.  Any  modifications  made  to  the  actuators  or  their 
accessories must be approved in writing by 

modec

Operators  in  charge  of  setting  up,  using  or  servicing 

modec 

actuators  must  have  a 

reasonable  knowledge  of  the  equipment.  As  well  as  carefully  reading  this  instruction 
manual, they must be competent in the valve sector and the particularities related to their 
work environment. 
 

KEEP THESE INSTRUCTIONS 
This  manual  contains  important  information  and  user  instructions  for  the 
following tools: water kit 

modec

. It is IMPERATIVE that you read the whole of 

this  user  guide  before  using  the  tool  or  carrying  out  any  maintenance 
operations. Make sure you follow to the letter the instructions and diagrams 

found in this document. Failure to adhere to the instructions contained in this manual, and 
any modifications, omissions  or  the  use  of  replacement  parts  that  do  not  adhere  to  the 
specifications  set out in this manual, clears the manufacturer of all responsibility related 
to the protection of people and equipment. 

 

 

Содержание MC89 Series

Страница 1: ...INSTRUCTION MANUAL WATER KIT ENGLISH...

Страница 2: ...Portable Valve Actuator 11 Changing the battery pack 11 Settings 11 Setting up and use the water kit 13 General info 13 Setting up and use the water kit 13 Start 15 Torque reaction safety stop 15 Eve...

Страница 3: ...Its two Lithium Ion batteries guarantee up to one hour of continuous use The electronic torque limiter integrated in the actuator will allow you to easily and effectively protect your equipment from d...

Страница 4: ...otice Updates will be available on our website www modec fr It isimportant to refer to the website before setting up or using the actuator and before carrying out maintenance Any modifications made to...

Страница 5: ...distance within a radius that takes ac count of fixed points straps chains and any other torque retention system used To protect the operator we recommend that you do not use the PVAs if there is a r...

Страница 6: ...for example direct exposure to the sun to fire to water and to humidity There is a risk of explosion In case of damage or non conforming use of the battery vapors could escape Ventilate the work plac...

Страница 7: ...7 Certification CE...

Страница 8: ...for each rotation direction D1 D2 the possible torque settings depending on thehead used 2 Fixation ring to fix a strap for handling and carrying Not for torque management 3 Flange enables the attachm...

Страница 9: ...actual measurements Maximum level of weighted acoustic pressure A at the operator s location LPA 73 dB A Maximum level of weighted acoustic power A at the operator s location LWA 84 dB A Uncertainty...

Страница 10: ...rging time with standard charger BAT145 45 minutes Weight 0 7 kg Autonomy is measured with a load equal to 50 of the max torque Instructions for use The battery pack is delivered partially charged To...

Страница 11: ...off and free of anyload CHANGING DIRECTION OF ROTATION Switch to the left D1 rotation direction Right clockwise Switch to the right D2 rotation direction Left counterclockwise SETTING TORQUE LIMIT AND...

Страница 12: ...etting Torque lim setting 1 2 3 4 5 1 Max S rpm 8 9 10 11 12 Max T Nm 60 180 300 430 550 2 Max S rpm 12 14 15 17 18 Max T Nm 50 160 270 390 515 3 Max S rpm 38 44 51 57 63 Max T Nm 13 50 100 140 175 4...

Страница 13: ...eel being activated Setting up and use the water kit 1 Select the interface corresponding to the shape of the drive shaft and connect it to the telescopic fountain key Make sure that the ball on the s...

Страница 14: ...table valve actuator using the two spring loaded pullers Note The BA012 torque management system is only valid up to a maximum torque of 350 N m It varies according to the nature of the soil loose ear...

Страница 15: ...Release the On Off switch Install a correct torque reaction system Press the On Off switch again Events occurring when actuating a valve 1 If the actuator sounds a beep it means that the required tor...

Страница 16: ...s and shows the rotational speed Note 1 The instant speed indicator needs several revolutions before it can give a stable and regular speed In light of this you have to wait several seconds to get a r...

Страница 17: ...ead Maintenance and Servicing Take the machine to a registered modec distributor for servicing every 400 hours or at least once a month Maintenance operation Weekly Yearly or as needed Check and servi...

Страница 18: ...ll the applicable regulations It is advisable to keep a maintenance log for all maintenance tasks carried out on the actuator Prevent foreign bodies from entering the system by using a clean work surf...

Страница 19: ...sly The motor is faulty Contact a modec Service center modec Distributor Revolution counter option Symptom Screen status Probable causes Checks Solutions Repaired by The counter doesn t givea reading...

Страница 20: ...ue reaction arm is correctly attached to the flange ROTATION ADJUSTMENT D1 AND D2 See page 14 Telescopic valve key EB002 and the extension bar EB012 The EB002 telescopic valve key and its fixed extens...

Страница 21: ...21 INSERTING THE EB012 EXTENSION INTO THE EB002 TELESCOPIC KEY Instruction Manual modec Portable Valve Actuators The Portable Valve Actuators users manual videos 1 1 1 1 2 2 3 1 1 2 2...

Страница 22: ...r acceptance of bill is not performed on the agreed date even further to partial order performance may entail revision of the conditions thereof and the overall credit conditions granted B INTELLECTUA...

Страница 23: ...23 Notes Contact modec Mail sales modec fr Phone 33 0 4 75 40 27 15 Fax 33 0 4 75 40 27 36 www modec fr...

Страница 24: ...24 PRINT NOT KIT H20 EN 2022 v01...

Отзывы: