modec MC89 Series Скачать руководство пользователя страница 19

 

19 

 

 

Problem solving 

 

Electric Portable Valve Actuator MC89 

Symptoms 

Probable causes 

Checks & solutions 

Repairer 

The actuator 

doesn’t start 

Direction switch button is not 

activated 

Press switch correctly to the left or the 

right 

User 

Battery not properly in place 

Insert the battery correctly 

User 

 

The actuator beeps 

once and stops 

Battery pack is empty / not charged 

Charge / change the battery pack 

User 

Actuator overloaded (torque is too 

high) 

Reduce load 

User 

Actuator has overheated 

Let it cool down a few minutes 

User 

The actuator beeps 

once and the led 

flashes 

continuously 

 

Torque reaction safety has triggered 

 

Release the On/Off switch, fix a torque 

reaction system and start again 

 

User 

The actuator beeps 

continuously 

The motor is faulty 

Contact a 

modec 

Service center 

modec 

Distributor 

 

Revolution counter (option) 

Symptom 

Screen 

status 

Probable causes 

Checks 

Solutions 

Repaired by 

 

The counter 

doesn’t give a 

reading 

 
 

Off 

Timer elapsed / 

automatic stop 

 

Activate  the 

“ON” button 

User 

Flat battery 

Check the state of 

the battery 

Change the 

battery 

User 

Screen is out of 

order 

Check with a registered 

modec 

distributor 

Change the 

screen 

Modec 

distributor 

The counter is 

on but doesn’t 

count 

 

On and 

not 

moving 

Poor connection 

between the captor and 

the card 

Check the sensor 

connection 

Reconnect the 

sensor 

User / 

modec

 

distributor 

Captor and/or the 

card is out of order 

Check with a registered 

modec 

distributor 

Change the 

electronic card 

Modec 

distributor 

 

 

Accessories 

 

Foot held articulated reaction system BA012 

Maximum admissible torque: 350 Nm. 

Telescopic valve key 

(EB002) 

Foot held articulated 

reaction system 

(BA012) 

Portable valve 

actuator 

Содержание MC89 Series

Страница 1: ...INSTRUCTION MANUAL WATER KIT ENGLISH...

Страница 2: ...Portable Valve Actuator 11 Changing the battery pack 11 Settings 11 Setting up and use the water kit 13 General info 13 Setting up and use the water kit 13 Start 15 Torque reaction safety stop 15 Eve...

Страница 3: ...Its two Lithium Ion batteries guarantee up to one hour of continuous use The electronic torque limiter integrated in the actuator will allow you to easily and effectively protect your equipment from d...

Страница 4: ...otice Updates will be available on our website www modec fr It isimportant to refer to the website before setting up or using the actuator and before carrying out maintenance Any modifications made to...

Страница 5: ...distance within a radius that takes ac count of fixed points straps chains and any other torque retention system used To protect the operator we recommend that you do not use the PVAs if there is a r...

Страница 6: ...for example direct exposure to the sun to fire to water and to humidity There is a risk of explosion In case of damage or non conforming use of the battery vapors could escape Ventilate the work plac...

Страница 7: ...7 Certification CE...

Страница 8: ...for each rotation direction D1 D2 the possible torque settings depending on thehead used 2 Fixation ring to fix a strap for handling and carrying Not for torque management 3 Flange enables the attachm...

Страница 9: ...actual measurements Maximum level of weighted acoustic pressure A at the operator s location LPA 73 dB A Maximum level of weighted acoustic power A at the operator s location LWA 84 dB A Uncertainty...

Страница 10: ...rging time with standard charger BAT145 45 minutes Weight 0 7 kg Autonomy is measured with a load equal to 50 of the max torque Instructions for use The battery pack is delivered partially charged To...

Страница 11: ...off and free of anyload CHANGING DIRECTION OF ROTATION Switch to the left D1 rotation direction Right clockwise Switch to the right D2 rotation direction Left counterclockwise SETTING TORQUE LIMIT AND...

Страница 12: ...etting Torque lim setting 1 2 3 4 5 1 Max S rpm 8 9 10 11 12 Max T Nm 60 180 300 430 550 2 Max S rpm 12 14 15 17 18 Max T Nm 50 160 270 390 515 3 Max S rpm 38 44 51 57 63 Max T Nm 13 50 100 140 175 4...

Страница 13: ...eel being activated Setting up and use the water kit 1 Select the interface corresponding to the shape of the drive shaft and connect it to the telescopic fountain key Make sure that the ball on the s...

Страница 14: ...table valve actuator using the two spring loaded pullers Note The BA012 torque management system is only valid up to a maximum torque of 350 N m It varies according to the nature of the soil loose ear...

Страница 15: ...Release the On Off switch Install a correct torque reaction system Press the On Off switch again Events occurring when actuating a valve 1 If the actuator sounds a beep it means that the required tor...

Страница 16: ...s and shows the rotational speed Note 1 The instant speed indicator needs several revolutions before it can give a stable and regular speed In light of this you have to wait several seconds to get a r...

Страница 17: ...ead Maintenance and Servicing Take the machine to a registered modec distributor for servicing every 400 hours or at least once a month Maintenance operation Weekly Yearly or as needed Check and servi...

Страница 18: ...ll the applicable regulations It is advisable to keep a maintenance log for all maintenance tasks carried out on the actuator Prevent foreign bodies from entering the system by using a clean work surf...

Страница 19: ...sly The motor is faulty Contact a modec Service center modec Distributor Revolution counter option Symptom Screen status Probable causes Checks Solutions Repaired by The counter doesn t givea reading...

Страница 20: ...ue reaction arm is correctly attached to the flange ROTATION ADJUSTMENT D1 AND D2 See page 14 Telescopic valve key EB002 and the extension bar EB012 The EB002 telescopic valve key and its fixed extens...

Страница 21: ...21 INSERTING THE EB012 EXTENSION INTO THE EB002 TELESCOPIC KEY Instruction Manual modec Portable Valve Actuators The Portable Valve Actuators users manual videos 1 1 1 1 2 2 3 1 1 2 2...

Страница 22: ...r acceptance of bill is not performed on the agreed date even further to partial order performance may entail revision of the conditions thereof and the overall credit conditions granted B INTELLECTUA...

Страница 23: ...23 Notes Contact modec Mail sales modec fr Phone 33 0 4 75 40 27 15 Fax 33 0 4 75 40 27 36 www modec fr...

Страница 24: ...24 PRINT NOT KIT H20 EN 2022 v01...