EN
61
Display
Operating Procedure
Description
“Barista” Programming
Group Dose
Settings
Pre-Inf
Settings
• This parameter allows the operator to
program the time of pre-brewing of
water with the coffee.
• The time (in seconds) for which the
brewing valve is open during the pre-
brewing cycle and the time (in seconds)
for which the brewing valve is closed
during the pre-brewing cycle; during
this time the pump is active. Once the
pre-brewing cycle is over, the normal
brewing cycle will continue until the
end.
• For an espresso machine composed of
two groups, they are identified as Group
1 and Group 2.
Pre-Infusion or Pre-Brewing
Pre-Inf
WITHOUT PUMP
5
Press the T3 button
to access the menu, then navigate using T1
and T2
to choose between
WITHOUT PUMP
and
WITH PUMP
, press the T3 button
to confirm the option.
Pre-Inf Settings
Exit
6
Press T1 or T2 until the display shows the exit menu, press the T3 button
to return to the “Barista”
programming.
7
Press T1 or T2 to continue with the programming of the other parameters.
G1
█
MODBAR G2
█
163Puls 0Puls
8
Press T2
and T3
at the same time to exit the programming mode and return to the normal use of the
espresso machine.