06. THE CHANGE OH THE DIRECTION OF THE WORK OF TUBULAR MOTOR
Fig. 6.1
a
e
b
c
d
07. DELETING CODES FROM ALL REMOTE CONTROLS FROM THE MEMORY OF
TUBULAR MOTOR
1. Enter the MR tubular motor in the PROGRAMMING MODE -
Fig.7.1a
;
until the drive performs one sequence of micro down / up movements.
2. On optional remote, which we wish to program as MASTER, press and simultaneously hold
STOP
and
UP
buttons for more than 5 seconds. This remote becomes the MASTER remote
and all other remote controls shall be deleted form the memory of the tubular motor. The
drive makes two micro-turns confirming the operation. -
Fig. 7.1b
;
Fig. 7.1
ON OFF
ON OFF
2x
b
a
ATTENTION
MASTER
can only be deleted replacing it with a new one.
08. DELETING CODES FROM ALL REMOTE CONTROLS FROM THE MEMORY OF
TUBULAR MOTOR
There is a possibility to delete only one of the programmed remote controls.
To do so you must:
Fig. 8.1
MASTER
PILOT 2
b
a
1. Press and simultaneously hold, on MASTER remote control,
STOP
and
UP
buttons for more
than 5 seconds until drive makes two micro-turns confirming entering into THE PROGRAM-
MING MODE.-
Fig. 8.1a.
2. Press and hold
STOP
and
UP
for more than 1 second on the remote (channel) we wish to
delete. Drive shall make two micro-turns and the code of the remote (channel) shall be deleted
form the memory of the tubular motor.
ATTENTION
If within 20 seconds none of the procedures shall be commenced – tubular motor
shall return to it’s work mode.
09. POWER SUPPLU SCHEME
L1
N
PE
230V~ 50Hz
MOBILUS MR
a
b
L1
N
PE
a)
TUBULAR MOTOR
b)
CONNECTION BOX
PHASE
NEUTRAL
EARTH
3