MOBILUS C-MR Скачать руководство пользователя страница 3

3. LOADING THE MASTER-A * CODE TO THE RECEIVER MEMORY

1.  Enter the 

MOBILUS C-MR

 PROGRAMMING MODE.

2.  Press and hold the 

STOP

 and 

UP

 buttons 

simultaneously on the remote control until the connected 

actuator executes one sequence of noticeable and audible 

micro movements down / up. 

3.  The 

MASTER

-a code has been loaded into memory and 

the module goes to the WORK MODE. Now, with the 

MASTER

 remote control, you can operate the units or enter 

the PROGRAM MODE to load more remote controls.

BEEP! BEEP!

PILOT 2

1 s.

b

5 s.

BEEP! BEEP!

WARNING 

In the case of a multi-channel remote control 

select only one channel to be 

MASTER

NOTE

 For the convenience of programming, it is recom-

mended that each 

COSMO | C-MR

 module had its own 

separate 

MASTER

 (remote control (separate channel for 

multi-channel remotes). 

Avoid situations where several 

COSMO | C-MR modules remote controls will have 

common MASTER (shared channel)

.

BEEP! BEEP!

MASTER

1

2

3

4

5

5 s.

BEEP! BEEP!

PILOT 2

1 s.

a

b

1

2

3

4

5

1

2

3

4

5

*MASTER

 - remote control or channel (in the case of a multi-channel remotes) loaded first into 

the memory of the 

MOBILUS C-MR 

module. Allows you to program further remote controls.

3

Содержание C-MR

Страница 1: ...User Manual of MOBILUS C MR external receiver www mobilus pl...

Страница 2: ...n of the equipment When designing the location of the remote control consider limiting the range to about 20m by 2 walls Declaration of Conformity We declare under our sole responsibility that the MOB...

Страница 3: ...reremotecontrols b 5 s BEEP BEEP WARNING In the case of a multi channel remote control select only one channel to be MASTER NOTE For the convenience of programming it is recom mended that each COSMO C...

Страница 4: ...ld both STOP and UP buttons simultaneously until the connected actuator performs one sequence of noticeable and audible micro movements down up The remote channel was loaded into the receiver s memory...

Страница 5: ...ttons Fig 5d until the drive executes one sequence of micro down up moves 2 Check the UP DOWN buttons Fig 5e Fig 5 a e b c d 6 C MR MODULE RESET FACTORY SETTINGS WARNING RESTORATIONOFFACTORYSETTINGSer...

Страница 6: ...ne sequence of noticeable and audible micro movements down up confirming the receiver s entrance into the programming mode Fig 7a Additionally in this mode every 1 sec the diode is blinking 2 On the r...

Страница 7: ...hold the STOP and MASTER buttons until the connected actuator executes one sequence of noticeable and audible micro movements down up In both cases the return to operating mode will be through one seq...

Страница 8: ...CONTINUED 8 CONNECTING THE ADDITIONAL SWITCH DRIVER Fig 8 2 c L1 N PE N PE 230V 50Hz a c b Fig 8 3 L1 N PE N PE 230V 50Hz a b c 8...

Страница 9: ...he connected actuator performs one sequence of noticeable and audible micro movements down up confirming the receiver entrance in the PROGRAMMING MODE Fig 9a Additionally in this mode every 1 sec the...

Страница 10: ...nthismodeevery1sec thediodeisblinking 2 Ontheremotecontrol pressthebuttonsequence UP STOP DOWN UP STOP DOWN Activationof therepeaterfunctionwillcausethreesequencesofDOWN UPmicro movementsbytheactuator...

Страница 11: ...hanging the operating mode the module will exit from the PRO GRAMMING MODE Fig 11 1b Fig 11 1 b x3 a To deactivate CONTINUOUS MODE repeat the procedure in steps 1 and 2 IN THE CONTINUOUS MODE the func...

Страница 12: ...e of pilots with bidirectional communication Remote controls supporting two way communication MOBILUS COSMO HCT COSMO G3 COSMO HM COSMO HB COSMO WT9 COSMO WT 13 BIDIRECTIONAL INFORMATION ABOUT THE POS...

Страница 13: ...verload detection active Fig 14b 3 To stop the overload detection repeat step 1 Then press the STOP button on the MASTER control and hold until the actuator connected to the MOBILUS C MR module will p...

Страница 14: ...begin to rise 3 At the moment when the user presses the STOP key the new relay operating time is saved Fig 15c Fig 15 b MASTER a c 16 PRODUCT DESCRIPTION L1 N PE 230V 50Hz L1 N PE 230V 50Hz b a a Prog...

Страница 15: ...HCT HB HM G3 15 17 CONTROL REMOTES COSMO SERIES WT WT9 L1 L5...

Страница 16: ...MOBILUS MOTOR Sp ka z o o ul Mi towa 37 61 680 Pozna PL tel 48 61 825 81 11 fax 48 61 825 80 52 VAT NO PL9721078008 www mobilus pl Wersja 1 0ENG 161124...

Отзывы: