13
CONTINUED 14. BI-DIRECTIONAL - OVERLOAD INFORMATION
Enable / disable of overload detection:
1. At the
MASTER
remote control press and hold the
STOP
and
UP
buttons simultaneously
until the connected actuator performs one sequence of noticeable and audible micro
movements down / up confirming the receiver input into the programming mode
- Fig. 14a
.
Additionally in this mode every 1 sec. the diode is blinking.
2. On the
MASTER
, press the
STOP
button and hold until the actuator connected to the
MOBILUS C-MR
module will perform two sequences of noticeable and audible micro
movements down / up. Overload detection active
- Fig. 14b
.
3. To stop the overload detection, repeat step 1. Then press the
STOP
button on the
MASTER
control and hold until the actuator connected to the
MOBILUS C-MR
module will perform 1
sequence of noticeable and audible micro moves down / up
- Fig. 14c
.
Fig. 14
b
MASTER
a
2x
c
15. SETTING OF THE SWITCHING TIME OF RELAYS
MOBILUS C-MR
allows you to change the relay switching time. This operation is necessary, for
example, for very high shutters. By default this time is 120 seconds.
1. Press
MASTER
at the same time and hold the
STOP
and
UP
buttons until the connected
actuator performs one sequence of noticeable and audible micro movements down / up,
confirming the receiver entry into the programming mode
- Fig. 15a
.
Additionally in this mode
every 1 sec. the LED flashes.