8.6. Impianto idraulico / Hydraulic system
Verifica /
Verification
Tempo richiesto
Time required
10’
Personale necessario
Personnel required
1
Strumenti
Equipment
Attrezzi da banco
Tool kit
Materiale
Materials
Nessuno
None
Descrizione
Description
Verificare il corretto livello dell’olio nel serbatoio; appurare l’assenza di trafilamenti
dall’impianto idraulico e di perdite dai cilindri idraulici e accertare l’integrità dei tubi
idraulici.
Check that the oil in the tank is at the correct level; verify there are no leakages in the
hydraulic system and in hydraulic cylinders. Check the integrity of the hydraulic pipes.
NOTE
Per verificare il corretto livello dell’olio nel serbatoio: con
sollevatore chiuso, rimuovere il coperchio del box centralina
idraulica e accertarsi che il livello dell’olio nel serbatoio sia
sopra la tacca del livello “MIN” e sotto la tacca del livello
“MAX”; se necessario rabboccare con olio ISO 15 (ex
TEXACO RANDO HDZ 15). Ad operazione ultimata,
riavvitare il tappo.
NOTE
To check the oil level in the tank when lift stowed,
remove the cover of the hydraulic unit and check that
the oil level in the tank is above the ‘MIN’ mark and
under the ‘MAX’ mark. If necessary fill up with oil
ISO
15
(ex
TEXACO RANDO HDZ 15
). At the end of the
operation, screw the cap.