Mobi Technologies 70117 Скачать руководство пользователя страница 3

Temperature Indicators 

 

This thermometer has a fever indication light.  

 

A Green LED will light up around the Power/Scan button if the temperature is between 
93.2°F(34.0°C) ~ 100.3°F(37.9°C).  

 

A Red LED will light up around the Power/Scan button if the temperature is between    
100.4°F(38.0°C) ~ 109.4°F(43.0°C) 
 

Note: If thermometer is placed too far away to take temperature the LED will light up BLUE and beep until 
in the proper position. 

 

Measurement Preparation for Best Results 

 

For more accurate measurements always store the device in same environment it is being used, for 
at least 30 minutes prior. An unexpected fluctuation of ambient temperature is likely to lower 
measuring accuracy.  

 

Do not talk or move body during measurement. 

 

Make sure to dry forehead & clear any excessive hair which may cause inaccurate reading. 

 

The infrared sensor must be kept clean, dry, and undamaged to ensure accurate results.  

 

External factors may influence forehead temperatures, particularly when the individual has been:  

o

 

Exposed to very hot or cold temperatures. 

o

 

Recently exercised, bathed, or other physical exertion as this 

increase’s

 temperature. 

 

Ensure the thermometer is correctly placed before taking the reading. Reference the sections below 
for how to best position the thermometers for each reading method. 

 

Use of this device is not intended as a substitution for consultation with your physician. 
Measurement results are for reference only. Contact your physician if you have or suspect and 
health concerns. 

Forehead Temperature

 

 

Forehead results will display from 89.6 

°F to 109.2 °F (32.0 °C to 42.9 °C). 

HI

 is displayed for all results 

above 109.2 °F (42.9°C), and 

LO

 is displayed for result below 89.6 °F (32.0°C). 

 

 

E

nsure the unit is in ‘

forehead 

mode’. 

In the upper left-hand corner, there will be an icon of a head. 

If you do not see the head icon in the upper left-hand corner, p

ress and release the ‘MODE’ button 

to switch mode until the correct icon displays on screen.  

 

For optimal results point the unit towards the forehead holding the probe 0.4 - 2 inches away from 
the forehead. 

 

Ensure you point the unit first, then press and release the ‘ON/Scan’ 

button. Scanning before 

correctly positioning the thermometer will result in inaccurate readings. 

 

Allow 1-

2 seconds after pressing the ‘ON/Scan’ 

button for temperature to display (if the sound is on 

the thermometer will ‘beep’).

 

 

Please remove any obstructions like hats, beanies, headbands, and hair for accurate reading.  

 

Please remember to take temperature in a controlled environment where direct sunlight or cold air 
will not affect the measurement. 

 

Please wait a few minutes before taking the temperature of an individual who has been exposed to 
extreme heat or sever cold weather.

 

 