6. TECHNICAL MESSAGES AND STATUS FEEDBACK 

 

Technical messages 

 
In case of a technical problem, the administrator receives an SMS message. Possible technical 
messages are: 
 

Message  

Reason  

Low batteries, external power supply 
OK 

Power is available, batteries need to be replaced 

No external power supply, batteries OK  No external power supply, batteries are capable to 

take over operation in low power mode 

Low batteries, no external power 
supply 

No external power supply, batteries need to be 
replaced 

External power supply OK, batteries 
OK 

The external power is restored (or the adapter is 
plugged in a socket), batteries do not need to be 
replaced 

Message(s) missed due to 
Network/SIM failure 

One  or  more  SMS  text  messages  couldn’t  be  sent, 
due to a SIM card failure or GSM network failure.  

 
When receiving one of the above mentioned technical messages, please take appropriate action 
as soon as possible. During the battery replacement, the SIM card does not have to be removed.  

 
Status feedback 
 

Status 

LED pattern 

Required action 

Module not configured 

Blinking 1 second on / 1 
second off 

Configure at least one telephone 
number  

Module is switched on, 
powered by batteries 

1 flash every 3 seconds 

No action required 

Module is switched on, 
powered by an external source 

On 

No action required 

Module establishes network 
connection to send an alarm 
message 

Blinking 2 seconds on, 1 
second off  

Wait until the network connection 
is established and the message 
is sent 

Module establishes network 
connection to get to program 
mode 

Blinking 3 seconds on, 1 
second off  

Wait until the network connection 
is established before 
programming  

No GSM connection 

2 flashes every 3 seconds  Try the SIM card in any mobile 

telephone; replace SIM card 
using other telecom provider; try 
the module at another location  

No valid SIM card or wrong PIN  3 flashes every 3 seconds  Try the SIM card in any mobile 

telephone; remove PIN code; 
check credit; replace SIM card 

Successful programming action  Blinking 3 times 

No action required 

Faulty programming action 

Flashing 5 times 

Check SMS command 

Low batteries 

4 flashes every 3 seconds  Replace both batteries 

 
 

 
 

 

Содержание PowerGuard CM2100

Страница 1: ...USER MANUAL Mobeye PowerGuard CM2100 SW version 1 n...

Страница 2: ...from moisture heat and water splashing The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment w...

Страница 3: ...ossible General settings 6 4 4 1 Phone numbers 6 4 4 2 Identification text 7 4 4 3 Alarm text 7 4 4 4 Alarm notification type SMS or SMS call 7 4 4 5 Power failure delay time 7 4 4 6 Input type 7 4 4...

Страница 4: ...rammed The SMS message contains the text Mobeye Power failure In case the power is restored the Mobeye PowerGuard sends a power restored SMS text message to the phone numbers as programmed In case one...

Страница 5: ...hould be programmed 2 3 CONNECT THE UNIT TO THE EXTERNAL POWER SUPPLY Connect the external power adapter or any other regulated 12VDC power supply to the power input of the connector V black lead with...

Страница 6: ...o switch off disarm the Mobeye PowerGuard Press the on off button at the upper side for 1 second The green LED switches off to indicate the armed status In order to switch on arm the Mobeye PowerGuard...

Страница 7: ...nput 1 It does not matter which wire is connected to which connector If necessary the wires can be extended up to 5 meters using appropriate wire material When using a second input connect this to inp...

Страница 8: ...be used The initial security code is 1111 In this manual this code is referred to as CODE 4 3 PROGRAMMING THE SETTINGS BY SMS The settings are programmed by SMS text messages Be sure the PowerGuard i...

Страница 9: ...ult behaviour after a power failure or an activated input the Mobeye PowerGuard notifies by SMS text message followed by a telephone call beep signal The combination of SMS text and the call increases...

Страница 10: ...size the urgency of the alarm messages all alarms can be repeated As long as the alarm status has not returned to the inactive status the SMS alarm will be repeated after the alarm repeat time The tim...

Страница 11: ...NO Input type input 2 TYPEIN2 type NO NC NO Delay on input 1 DELAY1 sec 0 999 sec 1 Delay on input 2 DELAY2 sec 0 999 sec 1 Inactive time input 1 INACTIVEIN1 min 0 60 min 0 Inactive time input 2 INAC...

Страница 12: ...The status message includes the ARMED NOT CONFIGURED status the status of the inputs and the status of the power and batteries 5 2 OVERVIEW GENERAL SETTINGS The general settings of the Mobeye PowerGu...

Страница 13: ...removed Status feedback Status LED pattern Required action Module not configured Blinking 1 second on 1 second off Configure at least one telephone number Module is switched on powered by batteries 1...

Страница 14: ...x ca 500 mA Dimensions 80 x 60 x 40 mm Ambient temperature 10 C until 50 C This manual is published by Mobeye All rights the translation included are reserved Any reproduction either photocopy microfi...