Mobeye MS100EK Скачать руководство пользователя страница 20

18 

CODE COMMAND:OPTION 

CODE 

COMMAND

:

OPTION

#

COMMAND

:

OPTION

#

COMMAND

:

OPTION

 

Setting 

 

Menu/ 
command 

Options 

Factory 
default 

TEL3 

Keypad 

103 

Telephone number 

 

SMS 

TEL3: 

TEL4 

Keypad 

104 

Telephone number 

 

SMS 

TEL4: 

TEL5 

Keypad 

105 

Telephone number 

 

SMS 

TEL5: 

Delete telephone 
number 

Keypad 

101…105 

 

SMS 

DEL1….DEL5 

 

Authorise telephone 
number 

Keypad 

201…250 

Tel. number 

 

SMS 

TELA1: ...TELA50: 
of ADDTELA: 

Delete authorised 
number 

Keypad 

201…250 

 

SMS 

DELA:1..DELA:50   

Authorised remote 
control 

Keypad 

90 

ON, OFF 

ON 

SMS 

AUTH: 

Identification text 

Keypad 

 

 

SMS 

NAME: 

20 characters 

Mobeye 

Alarm text power 
failure 

Keypad 

 

 

SMS 

TEXT2: 

20 characters 

Power 
failure 

Alarm text power 
restored 

Keypad 

 

 

SMS 

TEXT3: 

20 characters 

Power 
restored 

Alarm text input 1 

Keypad 

 

 

SMS 

TEXT4: 

20 characters 

Alarm 1 

Alarm text input 2 

Keypad 

 

 

SMS 

TEXT5: 

20 characters 

Alarm 2 

Text restored input 1 

Keypad 

 

 

SMS 

TEXT6: 

20 characters 

Input 1 
restored 2 

Text restored input 2 

Keypad 

 

 

SMS 

TEXT7: 

20 characters 

Input 2 
restored 

 

Program method using the keypad: 

 
CODE    

menu

    menu nr.    OK     option   OK 

 
Program method via SMS (in program mode): 
 

 
 
Or several commands at once: 
 

 
 

Leave the menu 

The menu can be left from any position, by pressing “OK” twice.  

 

Содержание MS100EK

Страница 1: ...Installation manual Mobeye MS100EK GSM Measure Control and Alarm module SW version 7 n...

Страница 2: ......

Страница 3: ...6 4 SMS ON OFF 11 6 5 CALL ON OFF 11 6 6 Interval test message 11 6 7 Set actual time and date 11 6 8 Automatic time based arm disarm 12 6 9 identification text 12 6 10 Alarm text 12 6 11 Input type 1...

Страница 4: ...2...

Страница 5: ...ternal use The guidelines for the battery usage must be regarded Do not expose the device to strong vibrations Do not let it fall from height Do not use in an environment where any inflammable gases v...

Страница 6: ...grammed The SMS message contains the text Mobeye alarm 1 or Mobeye alarm 2 As soon as the inputs leave the alarm status an SMS text message is sent to the set telephone numbers containing the text suc...

Страница 7: ...d at least once a month Open the back cover Insert the SIM card in the holder For opening closing move the cover slightly 2 2 CONNECT A SENSOR Open the hole in the enclosure and insert the 2 wires of...

Страница 8: ...n active The back up battery is able to power the module for at least 24 hours Close the Mobeye MS100EK using the 4 screws 2 5 PROGRAM THE PHONE NUMBERS You need to program at least one phone number i...

Страница 9: ...message is sent to all programmed alarm numbers next a phone call is made to the numbers When you answer the phone a beep tone is heard Confirm using 1 It is possible to confirm the phone call by ans...

Страница 10: ...ternal power source Please find below the architecture of the main unit Inputs External sensors can be connected to the inputs Upon closing or opening an input the Mobeye MS100EK will send an alarm me...

Страница 11: ...the SMS to OFF just call 1111 MENU 12 OK 0 OK 4 2 CONFIGURATION VIA SMS TEXT MESSAGES Almost all options can be set via the keypad except the texts It is also possible to program by sending SMS comman...

Страница 12: ...10 Or both commands in one message Example 1111 TEL2 4934578692 CALLALARM OFF Example To set the SMS to OFF just call 1111 CALLALARM OFF...

Страница 13: ...OFF By default the Mobeye MS100EK sends alarm notifications via text message and calls to the preset contact persons By turning off the SMS the unit will only call after the sensors send an alarm 5 5...

Страница 14: ...s soon as the terminals of the input are closed If the input is set to NC the alarm is triggered if the connection between the input terminals is broken The default input type is set to NO 5 12 INPUT...

Страница 15: ...eing authorised To disable the need for authorised numbers the authorization option can be set to OFF Default is ON 5 17 DURATION OF OUTPUTS SWITCH OR PULSE TIMES If an output is used the time this ou...

Страница 16: ...puts 2 Power failure Send SMS call 3 Power restored Send SMS 4 Input 1 triggered Send SMS call 5 Input 2 triggered Send SMS call 6 Input 1 restored Send SMS 7 Input 2 restored Send SMS The SMS texts a...

Страница 17: ...ION1 REACTION2 REACTION3 Do not forget the space between CODE and the TRIGGER The Mobeye MS100EK will play a short melody to indicate a successful configuration In case of a wrong command a long beep...

Страница 18: ...uence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its index number even if a rule with a previous number is deleted This will result in gap...

Страница 19: ...nput type input 1 Keypad 71 0 off 1 NO 2 NC 1 NO SMS TYPEIN1 OFF NO NC Input type input 2 Keypad 72 0 off 1 NO 2 NC 1 NO SMS TYPEIN2 OFF NO NC Inactive time Input 1 Keypad 73 0 999 min 5 SMS INACTIVEI...

Страница 20: ...OFF ON SMS AUTH Identification text Keypad SMS NAME 20 characters Mobeye Alarm text power failure Keypad SMS TEXT2 20 characters Power failure Alarm text power restored Keypad SMS TEXT3 20 characters...

Страница 21: ...t advised to test the GSM signal strength Enter the installation code Press menu Press 512 Press OK The Mobeye MS100EK will search for all available networks It also checks the network strength of the...

Страница 22: ...test No network is available belonging to the SIM cards provider Choose another network provider The light remains red You entered an incorrect installation or user code three times Wait 10 minutes a...

Страница 23: ...2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low volta...

Страница 24: ......

Отзывы: