Mobeye CM4300 Скачать руководство пользователя страница 4

Attention! Very important 

 
This user manual contains important guidelines for the installation and usage of 
the Mobeye

® 

device as described in this manual. Please read these thoroughly 

before you start using the Mobeye

® 

device. 

In the case of damage caused by disregarding the guidelines and the instructions 
for  use,  no  liability  is  accepted  and  the  warranty  becomes  void.  The  user  must 
regularly check the proper functioning of the Mobeye

®

 device. The manufacturer 

cannot  be  held  liable  for  (direct  and  indirect)  damage  as  a  result  of  incorrect 
operation  or  incorrect  functioning  of  the  device,  software,  internet  or  telecom 
connection.  The  manufacturer  is  in  no  way  liable  for  the  loss  of  personal 
passwords or codes. 
 

Safety guidelines 

• 

 The  permitted  ambient  temperature  during  operation  may  not  be  exceeded 

(not lower than -10 °C and not higher than 50 °C). 

• 

 The device is intended for use in dry and clean places. 

• 

 Protect the device from moisture, heat and water splashing. Not intended for 

external use. 

• 

 The guidelines for the battery usage must be regarded.  

• 

 Do not expose the device to strong vibrations. 

• 

 Do not let it fall from height. 

• 

 Do not use in an environment where any inflammable gases, vapors or dust are 

present or could be present.  

• 

 Repair of the device may only be carried out by people, trained for Mobeye

®

 

repair. 

• 

 If the device must be repaired, only original replacement components may be 

used. The use of different parts may lead to damage of the Mobeye

®

 device. 

 

Use in accordance with the regulations 

The purpose of this device in accordance with the regulations is sending messages 
and making telephone calls after an alarm situation. Other uses are not permitted 
and may invalidate the warranty. 
 

Battery recycling 

This product contains recyclable components. When disposing of this product, 
please take it to a waste collection point for disposal or to your sales point. Bring 
empty batteries to a recycling centre or collection point. 

Содержание CM4300

Страница 1: ...USER MANUAL Mobeye WaterGuard CM4300 SW version 1 n...

Страница 2: ......

Страница 3: ...Internet Portal 11 4 5 How to activate the WaterGuard 13 4 6 System reset 14 5 Possible settings 15 5 1 Alarm phone numbers 15 5 2 Test message 15 5 3 Input type 16 5 4 Alarm delay time 16 5 5 Inacti...

Страница 4: ...ended for use in dry and clean places Protect the device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be regarded Do not expose the de...

Страница 5: ...a network problem it will switch to another provider or fall back to 2G In addition the Mobeye SIM card offers access to the Mobeye Internet Portal This management environment gives the device essenti...

Страница 6: ...inputs remain in the alarm status the Mobeye WaterGuard repeats sending the alarm message via the Mobeye Internet Portal every four hours When an external power supply is used and a power failure occu...

Страница 7: ...m As soon as the water detection has ended an SMS text message is sent to the phone numbers programmed in by the user containing the text Water level OK When the water sensor is removed the Mobeye Wat...

Страница 8: ...g the Mobeye SIM Portal a Sign up in the Mobeye Internet Portal b Activate the SIM card and the device c Program the settings and synchronise d Use of the portal and app 7 Programming when using your...

Страница 9: ...the two batteries CR123 in the module Use the indication for the correct placement If you replace the batteries the settings will not be deleted since they are stored in the device memory 3 4 CONNECT...

Страница 10: ...recovery message after an alarm reset is desired see 5 7 3 6 NETWORK CONNECTION AND PROGRAM MODE After placing the batteries and external power the Mobeye WaterGuard will search for the network The ou...

Страница 11: ...tten on the plastic SIM card below the barcode You can take the entire number or only the last 8 digits If the SIM card and batteries are already installed a pop up will appear where you assign a name...

Страница 12: ...irst blink red green while connecting to the network 4 4 BASICS OF THE MOBEYE INTERNET PORTAL Dashboard With multiple devices the dashboard shows all devices with the alarm messages in the last 24 hou...

Страница 13: ...essages you link the contact persons who receive alarm and service messages via push notification call text message and or e mail Service messages can be warnings about missed test messages and low ba...

Страница 14: ...ed and to send test and low battery voltage messages In order to switch on arm the Mobeye WaterGuard Press the button at the backside for 1 second The green LED blinks once every 3 seconds battery pow...

Страница 15: ...pply 2 Press the outside button while reinserting the batteries Keep it pressed for about another 5 seconds 3 Release the button immediately after the LED starts to flash 4 If relevant connect the ext...

Страница 16: ...essage and checks the timely receipt The monitoring of the test messages follows the management by exception rule only if the message was not received the service contacts will receive a notification...

Страница 17: ...ive after an activation During the inactive time no new alarm message will be sent Only when the input returned to the non alarm status gets activated again and remains active an alarm will be sent ye...

Страница 18: ...alarm messages If the setting is OFF no message is sent When set to ALARM notifications are sent to the set contacts When using your own SIM card the setting ALERT only results in an SMS notification...

Страница 19: ...unit from being switched off unintentionally As default the buttonlock is unlocked so the button is enabled To disable the button the buttonlock needs to be switched to ON 5 12 LOW POWER MODE The low...

Страница 20: ...et In this program mode the device is ready to receive commands and settings In a battery operated unit a time out occurs if no correct command is received for 3 minutes after which the communication...

Страница 21: ...sages up to 5 telephone numbers The first telephone number TEL1 is mandatory This number will receive next to alarm message also system messages such as battery low and keep alive message The telephon...

Страница 22: ...Input type input 2 TYPEIN2 NO NC NO Input type water sensor TYPEIN3 NO NC NO Delay on input 1 DELAY1 0 999 sec 1 Delay on input 2 DELAY2 0 999 sec 1 Delay on water sensor DELAY3 0 999 sec 30 Inactive...

Страница 23: ...m Text water restore TEXT2 20 characters Water level OK Alarm text input 1 TEXT3 20 characters Alarm 1 Alarm text input 2 TEXT4 20 characters Alarm 2 Alarm text power failure TEXT5 20 characters Power...

Страница 24: ...once every 3 seconds battery powered or stays on continuously in case of an external power supply If powered externally with network connection switching can be done via SMS commands SMS command to s...

Страница 25: ...SMS command status request STATUS example 1111 STATUS LIST OF SETTINGS The settings can be requested by sending following SMS text message SMS command list basic settings SET SMS command list advanced...

Страница 26: ...replaced External power supply OK batteries OK The external power is restored or the adapter is plugged in a socket batteries do not need to be replaced delayed message If delayed message is added to...

Страница 27: ...he network connection is established 2 flashes red every 3 seconds No GSM connection Try the SIM card in any mobile telephone replace SIM card using other telecom provider try the module at another lo...

Страница 28: ...27...

Страница 29: ...on 12V ca 50 mA stand by max ca 500 mA Dimensions 94 x 94 x 28 mm Ambient temperature 10 C until 50 C This product is designed and manufactured in the Netherlands For more information visit www mobeye...

Страница 30: ...29...

Страница 31: ...30...

Страница 32: ......