Mobeye Call-Key Скачать руководство пользователя страница 23

21 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

This manual is published by Mobeye. 
All  rights,  the  translation  included  are  reserved.  Any  reproduction,  either  photocopy, 
microfilm  or  saved  in  an  automated  data  dictionary,  only  after  written  approval  of  the 
Publisher. Reprinting, even in summary, is prohibited.  
This user manual meets the technical requirements at the moment of printing. Changes 
in technology and equipment are reserved. 
 

© Copyright 2018 by Mobeye, version MCK100MIP-EN180401 

 

Declaration of Conformity

 

 

Herewith we, Mobeye,  declare that the product 

 

Mobeye XM2 telemetry module 

 

And the derived products 

MS100, MS200, MS300, Call-Key

 

 
 

are in compliance with the essential requirements of the following European standards / EU 
Directives:  

 

Directive 73/23/EEC 

(low voltage directive) 

 

Directive IEC/EN 50130 

Electromagnetic compatibility 

 

Directive 2014/53/EU (RED)

 

 

 
The conformity with the essential requirements set out in Art.3 of the 2014/53/EU has been 
demonstrated against the following harmonized standards:  

EN 60950-1: 2006 + A11 : 2009 + A1: 2010 + A12: 2011 + A2: 2013  
EN 62311 :2008  
EN 301 489-1 V2.1.1, Draft EN 301 489-52 V1.1.0  
EN 301 511 V12.5.1 

 
Mobeye B.V.

 

Poeldonkweg 5 
5216 JX ’s-Hertogenbosch  
The Netherlands

 

 
Name:  

 

J.P.K. van de Vijver,        

Position:   

General Manager 

Signature: 

 

 

Date:  

12 July 2017

 

Содержание Call-Key

Страница 1: ...Installation manual Mobeye Call Key GSM Door Opener In combination with Mobeye Internet Portal SW version 7 n...

Страница 2: ...er than 55 C The device is intended for use in dry and clean places Protect the device from moisture heat and water splashing Not intended for external use The guidelines for the battery usage must be...

Страница 3: ...ional settings 12 3 1 Standard behaviour 12 3 2 Installation code 13 3 3 Output behaviour Switch or pulse times 13 3 4 Input type 13 3 5 Input delay time 13 3 6 Inactive time 13 3 7 Alarm repeat time...

Страница 4: ...SMS in the stand alone module Phone numbers are authorized for 24 7 always Registered in the Mobeye Internet Portal This password protected and secured internet area offers additional functionality Fo...

Страница 5: ...he Mobeye M2M SIM card which was included in the delivery If no SIM card was included please ask Mobeye info mobeye eu The SIM card needs to be inserted before the batteries Open the back cover and in...

Страница 6: ...ted the Mobeye Call Key will send an alarm message in the event of a power failure After sending the outage report the unit itself will go to the Low Power mode which means that the GSM module will sh...

Страница 7: ...d Enter the SIM card number This is the number written on the plastic SIM card Only take the last 8 digits of the last two lines incl number after space do not insert the space Click next Select the d...

Страница 8: ...tion code is also included in the confirmation SMS which the administrator received after programming the administrator number For more security the code needs to be changed to a personal installation...

Страница 9: ...up was not done correctly click previous and try again If it still does not work please contact Mobeye info mobeye eu As soon as communication is set up next screen appears 1 Enter a name for the dev...

Страница 10: ...Portal lists the active devices Select a device and click it Note After entering the settings on the screen these are not automatically programmed in the Mobeye Call Key This only happens when you sy...

Страница 11: ...option not obligatory to set contact persons It is possible to connect several people to the messages It is possible to send alarm messages to a set of persons and the status messages to others Contac...

Страница 12: ...of access scan be granted 1 Unlimited access 2 Limited access with periods and time windows 3 Limited access for an unlimited period but limited time windows within the days Create a group name For un...

Страница 13: ...eries and reconnecting this power which will generate a power failure message to the contacts as well 2 9 HOW TO OPEN THE DOOR LOCK After the preceding steps the lock can be opened by authorised telep...

Страница 14: ...n the Mobeye Internet Portal in the part Options The settings will be picked up by the unit at a synchronisation run see 2 8 To prepare the settings the security code is needed The factory default for...

Страница 15: ...the time is set to 0 minutes the input is active again immediately after returning to the non alarm status If the time is set to e g 30 minutes the input remains inactive for the first 30 minutes If...

Страница 16: ...ed to only switch the output by an incoming call or SMS from an authorized phone there is also an option to let them be switched by any incoming call SMS without being authorised To disable the need f...

Страница 17: ...a beep is heard Setting SMS command Options Factory default Installation code INSTCODE 0000 9999 1111 Pulse time output 1 TO1 1 999 sec 10 Pulse time output 2 TO2 1 999 sec 10 Input type input 1 TYPE...

Страница 18: ...Switch output 1 3 Input 1 triggered Send SMS call Message to portal call 4 Input 2 triggered Send SMS call Message to portal call 5 Power failure Send SMS call Message to portal call 6 Power restored...

Страница 19: ...iver will hear a 2 tone signal and can confirm by pressing 1 4 3 PROGRAMMING ACTION RULES Send following SMS commands in following format CODE TRIGGER REACTION1 REACTION2 REACTION3 Do not forget the s...

Страница 20: ...be deleted by an SMS by the command below incl index number The index number is the sequence number of the action rule as displayed in the ARLREPORT CODE DELARL indexnumber Remark a rule will keep its...

Страница 21: ...3 short beeps Release the button Connect the power and insert the batteries if available After a successful reset the status LED will flash red to indicate that the module is not configured The secur...

Страница 22: ...e another network provider For other questions please refer to the site www mobeye eu Technical data GSM Quad Band EGSM 850 900 1800 1900 MHz compatible to the ETSI GSM Phase 2 standard Temperature ra...

Страница 23: ...XM2 telemetry module And the derived products MS100 MS200 MS300 Call Key are in compliance with the essential requirements of the following European standards EU Directives Directive 73 23 EEC low vol...

Страница 24: ......

Отзывы: