CODE COMMAND:OPTION
3.11 ALTERNATIVE WAY OF PROGRAMMING VIA SMS COMMANDS
In the event that the Internet Portal is out of order and the settings need to be changed, it is
possible to change the settings via SMS commands. Please follow next steps:
- Be sure the unit is connected to an external power supply
- Send an SMS message with following content:
- The CODE stands for the installation code. Factory setting is
‘1111’.
- Do not forget the space between CODE and COMMAND.
- The commands are case sensitive.
- All settings are stored in the unit and will be kept when removing the power supply.
A confirmation melody is played to indicate a correct command. In the event of an incorrect
command, a beep is heard.
Setting
SMS
command
Options
Factory default
Installation code
INSTCODE:
0000...9999
1111
Pulse time output 1
TO1:
1...999 (sec)
10
Pulse time output 2
TO2:
1
…999 (sec)
10
Input type input 1
TYPEIN1:
NO, NC
NO
Input type input 1
TYPEIN2:
NO, NC
NO
Inactive time input 1
INACTIVEIN1:
0...60 (min)
0
Inactive time input 2
INACTIVEIN2:
0...60 (min)
0
Delay time input 1
DELAY1:
0...60 (sec)
1
Delay time input 2
DELAY2:
0...60 (sec)
1
Alarm suspension input 1
SUSPEND1:
0···999 (sec)
0
Alarm suspension input 2
SUSPEND2:
0···999 (sec)
0
Power failure delay time
DELAYPOW:
0...999 (min)
1
Interval test message
TEST:
0...30 (days)
7
Authorised switching/remote
control
AUTH:
ON, OFF
ON
To request the settings:
After data exchange the new settings are listed in the portal.
Alternatively, they can be requested by CODE
SET?
To request the status:
CODE
STATUS?
Example:
to set the pulse time of output 1 to 20 seconds:
1111 TO1:20