MOBATIME BE-801181.00
Change to the thermometer IP address:
setting is carried out using the Ethernet Configurator software (Downloads
http://www.papouch.com/cz/shop/product/tme-ethernetovy-teplomer/ethernetconfigurator.zip)
following the start all thermometers connected to the LAN local network and the respective
IP addresses are displayed in the upper window
choose the IP of the thermometer you want to set and depress the Set Device button
edit the IP address or other contingent parameters in the bottom window
by depressing the Set button send away the actual setting data to the thermometer.
Reset of thermometer:
Reset is carried out using the following procedure:
disconnect power supply from the device
open the electronic box by screwing off screws on the sides
insert the shortcircuiting jumper in the inside of the device and keep it short-circuited
switch the power supply on and wait for 10 seconds
the process of resetting is now finished
Set communication mode to TCP Server:
after setting the TPHP LAN
’s IP address, you can connect to it by any WEB browser. WEB
interface is the primary means to configure the thermometer. (For example by entering
http://192.168.1.254/ - for default IP address.)
t
o enter settings, push “Settings” button in upper right corner of TPHP LAN main WEB
set communication mode to TCPServer
factory device default set