2 Configuration
The movements SEM 40 / SAM 40 V2 have 12 DIP switches on the housing back side. The following
configuration settings are possible:
Switch:
Position OFF:
Position ON:
1
ON
1 2 3 4 5 6 7 8 9 10 1112
Movement runs on time (if syn-
chronized and no other
MOBALine command is active)
Movement runs to 12:00 position
2
ON
1 2 3 4 5 6 7 8 9 10 1112
Second hand in stepwise mode Second hand in continuous
mode
3
ON
1 2 3 4 5 6 7 8 9 10 1112
Minute hand in stepwise mode
Minute hand in continuous mode
4 - 8
ON
1 2 3 4 5 6 7 8 9 10 1112
Clock runs on the line time giv-
en out by the master clock:
4: 0
5: 0
6: 0
7: 0
8: 0
Selection of world time zone (bi-
nary value):
4: 1
5: 2
6: 4
7: 8
8: 16
9
ON
1 2 3 4 5 6 7 8 9 10 1112
Standard
Swiss Railway Mode (SBB).
Overwrites the settings done with
DIP switches 2 and 3.
10
ON
1 2 3 4 5 6 7 8 9 10 11 12
Second and minute hand
modes are defined by DIP
switches (2/3/9)
Second and minute hand modes
are defined by MOBALine (with
DCF active, this switch is not
used)
11 - 12
-
No function
No function
Recommendation: Set configuration switches prior to applying power (MOBALine signal).