© MOBATIME
27 / 52
801314.00
6
Control of the stopwatch via keyboard
The operation of the stopwatch is controlled and the device is adjusted using three
pushbuttons on the connected keyboard. The keyboard cable must be connected to the CTRL
plug connector.
Abbreviations used for the key strokes
PB1L, PB2L
pushing of the pushbutton for a period of
more than 1 second
PB1S, PB2S, PB3S
short-time pushing of the pushbutton
Function of the pushbuttons in the “Stopwatch“ mode
PB2S
indication switch over:
time - date - temperature - stopwatch - time
PB2L
stopwatch menu
PB3S, PB1S, PB1L
according to the stopwatch mode setup
6.1
The stopwatch menu
The stopwatch menu is entered by long pushing of the
PB2
pushbutton
(stopwatch must be displayed). The parameter adjustment is to be performed
according to the menu table (chapter 8).
Function of the pushbuttons in the “Stopwatch Menu“ mode
PB1S
move to another menu item
PB1L
storage of the parameters; return to the
stopwatch display mode when counting up from
zero; or entry into the initial time setting mode
when counting down
PB2S
increase of the current value, in steps of 1
PB2L
continuous increase of current value
6.2
Setting of the initial time for counting down
When counting down is selected, the initial time setting mode is entered from the
stopwatch MENU or directly from the “Stopwatch” display mode by pushing the
PB1L
button. The item to be set is blinking.
By pushing the
PB2S
button is the adjusted value increased in steps of 1, by
pushing the
PB2L
button will be the value continuously increased. By pushing
PB1S
move to the next item. By pushing the
PB1L
save the setting and return to
“Stopwatch” display mode.
Enter the data in the following order depending on the item
S2
setting (unit):
By pushing the
PB1L
button, the entered values are stored and the clock
returns to the “Stopwatch” display mode.
Counting unit
Data order
1/100 second
<Minute>:<Second>.<Hundredths of
second>
1 second
<Hours>:<Minutes>:<seconds>.
1 minute
<Hours>:<Minutes>
1 day
<Days>