background image

Abb. 1

 /

/

Remote control

 

1

2

3

4

5

10

9

7

6

8

1.

 Outer protective grille– protects the system from humidity even during heavy rains.

2.

 Extensible air funnel – allows regulation of the system length, depending on wall thickness.

3.

 Exhaust fan – two-speed, allows regulation of fan duty from 45m³/h in night silent mode, up to 70m³/h in day mode.

4.

 Filter with charcoal – guarantees the clean airflow even in strong polluted urban areas and industrial regions. Cleans the air from smells, dust, 

    bacteria, soot, car exhaust gases and other.

5.

 Heat exchanger – contributes to a significant reduction of heat loss during ventilation.

6.

 Ionizer – filling up the air with negative ions.

7.

 Blast fan – two-speed, allows regulation of fan duty from 45m³/h in night silent mode, up to 70m³/h in day mode.

8.

 Decorative grille – does not take any space in the room, can be executed  in different colors.

9.

 Control unit with humidity sensor – switches on the ventilation when humidity exceeds 75%.

10.

 Ceramic heater - (

Heater with positive temperature coefficient

self-regulating 

(

500~50W

)

 and economical

.)

Remote control (Fig.1):

11.

 

The airflow system  ”Eco-Fresh 01 LUX” is composed of:

11

Start/Stop         – 

switches on/off the system.

 
 

AIR FLOW

 

- Mode (reversible ventilation with thermal energy recovery).
The system blasts clean air from outside to inside and disposes polluted air out of the room.  A heat recovery is observed – process of recovering 
heat from outgoing warm but polluted air. The warm air which is going out through exchanger is rendering its heat to the incoming clean air. 
This contributes to a significant reduction of heat loss during winter days. In summer the opposite process is observed – the cool air from 
air-conditioning which is going out through exchanger is chilling the incoming clean but warm air. In the exchanger is achieved efficiency of heat 
regeneration that exceeds 90%. 

AIR FLOW

 

-  mode “Air Influx” – the system is constantly submitting clean air from outside to inside.

The heater can be switched on only in this mode and 

   

delivers fresh air with temperature 23

°

C.

AIR FLOW

 

- mode “Air Exhaust” – by protracted press over 10 seconds the system is working as a fan.

SLEEP

In sleep mode and without light in the room the system turns off automatically after 10 minutes.
At lightening the system will be in working mode after 2 hours retaining the previous settings. 

STANDBY

 

Heater, fan and ionizer are stopped. But the hydrostatic system monitors the humidity and when it exceeds 75% the fan and ionizer are 
automatically switched on. They stop working 10 minutes after the humidity level drops below 75%.

FAN SPEED

operate the fan speed.  A selection between 5 speeds – first speed – 45m³/h in night silent mode, and last fifth speed – max. 70m³/h in day mode. 

ON/OFF

     - switch on/off the hydrostatic system;

ON/OFF     

switches on/off the ionizer;

ON/OFF     

switches on/off the mode “heating of incoming air”.