MMD PowerPro Inverter Generators • IGR6000H (091615)
MMD PowerPro Inverter Generators • IGR6000H (091615)
Page 36
Page 37
9. Wheel Kit
1. Washer
4. Wheel
3. Lock pin
4. Locking swivel wheel
5. Bolt M6X16
To install the front wheels, install a
washer on the axle, then the wheel,
another washer and secure with a wheel
clip.
To install the locking swivel wheels, line
up the bolt holes in the chassis with
the holes in the wheel attaching plate.
Secure with the 4 bolts.
1. IG6000H Chassis- installed
2. Support Bracket (4)
3. Front Stabilizer (2)
4. Axle Assembly
5. 10" Wheel
6. Wheel Washer (4)
7. Wheel Clip
Assembly:
1. Install the four support brackets and
secure with bolts.
2. Attach the front stabilizers to the
chassis (below the handles)
3. Attach the axle assembly.
4. Install one washer on the axle
against each welded stop.
5. Install the two wheels.
6. Install the two remaining washers
and secure with the wheel clips.
The handles are preassembled before
packaging. To raise the handles,
simply raise the handle assembly to
a horizontal position. To retract the
handles, slide the chrome collars toward
you to clear the sleeve and lower them
to the starting position.
Engine will not start
Problem/Possible cause
Corrective action
No fuel in tank
Refuel with gasoline
Fuel switch not on
Turn fuel switch to ON position
Not enough oil in engine
Refill with recommended oil
Fuel not reaching carburetor
How to check:
1. Turn off fuel valve and loosen drain screw
2. See if fuel is flowing from drain when fuel valve is turned
on.
If the engine still does not start, please take the generator
to an authorized sales representative.
No spark from spark plug
Check spark plug or replace spark plug
How to check spark plug:
1. Remove spark plug cap and clean any debris off sparkplug.
2. Remove spark plug and install spark plug in the plug cap.
3. Set the plug-side electrode on the cylinder head to the ground.
4. Pull the recoil starter. Sparks should jump across plug gap.
If the engine still does not start, please take the generator to an authorized sales representative.
Appliance does not operate
Problem
Corrective action
Output indicator not on
Check appliance/equipment for defects
Overload indicator on
1. Replace appliance/equipment, or have repaired.
2. Stop and restart engine and try again.
If still not operational, please take the generator to an authorized sales representative.
No power to the DC receptacle
Problem
Corrective action
DC circuit fuse blown
Replace fuse
If still not operational, please take the generator to an authorized sales representative.
10. Troubleshooting
Make sure there is no spilled gasoline around spark plug. Spilled fuel may ignite.